Experiment 3 procedures (source code)

= Experiment 3 procedures
{c}
{tag=Work by McMaster University}

Laboratory protocol in <Chem2O06 Laboratory Manual by McMaster University>. No individual author byline is established. The footer is dated 17 September 1997; the manual identifies the 1997/98 course edition.

Online text: https://www.chemistry.mcmaster.ca/~chem2o6/labmanual/expt3/exp3-p.html

Cited section: https://www.chemistry.mcmaster.ca/~chem2o6/labmanual/expt3/exp3-p.html[Part A: 25 mL cyclohexane plus 25 mL p-xylene; top of thermometer bulb midway in opening to condenser; Part A: heating mantle on ring clamp, clay boiling chip, roughly one drop per second; Part A and B: record head temperature every 2 mL until 45 mL collected; Part B: 100 mL round-bottom flask and fractionating column; proceed as above; Recording of Results: paired temperature-volume plots, no azeotrope for this pair, volume is not composition; Experimental Notes item 2 mentions condenser water flow; no inlet/outlet direction established.]