Colony-forming unit (source code)

= Colony-forming unit

A <colony-forming unit>, abbreviated CFU, is a unit of viable material that produces a distinguishable <colony (biology)> under specified assay conditions. It may begin as one <cell> or as a clump. Counting colonies therefore measures colony-producing units, rather than automatically counting every living cell in the original sample.<Bacteriological Analytical Manual Chapter 3: Aerobic Plate Count by the Food and Drug Administration (January 2026)>[Recording counts, p.8: chains arising from clumps and distinct sources]{ref}

A measured concentration also requires an accounting of sample volume and dilution. In a simple plate-count model with $n$ colonies, plated volume $V$ and dilution fraction $d$, the original-sample estimate is
$$
\widehat C=\frac{n}{Vd}.
$$
If $V$ is in millilitres, $\widehat C$ is in CFU per millilitre. The fraction $d$ is the amount of original sample in one volume of the diluted preparation; it is not the reciprocal dilution factor.<Bacteriological Analytical Manual Chapter 3: Aerobic Plate Count by the Food and Drug Administration (January 2026)>[SectionD, example2.2a, p.7: divide count by original-homogenate volume]{ref}

For an original benign-<yeast> example, suppose two matched measurements yield50 and70 colonies, each from $0.1\,\mathrm{mL}$ at $d=10^{-3}$. Pooling the counts and effective volumes gives
$$
\widehat C=\frac{50+70}{2(0.1)(10^{-3})}
=6.0\times10^5\,\mathrm{CFU/mL}.
$$
This assumes a well-mixed preparation, comparable recovery and distinct countable colonies. It is an arithmetic illustration, not a recommendation for culturing a particular organism.

A <culture medium>, incubation conditions and recovery state determine which viable units become visible. A zero count in a finite tested volume does not prove that no viable material exists anywhere in the sample. Crowded colonies, clumping and assay inhibition also affect interpretation; the method and its reporting conventions should accompany the result.<Bacteriological Analytical Manual Chapter 3: Aerobic Plate Count by the Food and Drug Administration (January 2026)>[Recording counts, p.8: spreaders and plates with no CFU]{ref}