Dosimetry of Small Static Fields Used in External Beam Radiotherapy by the International Atomic Energy Agency (source code)

= Dosimetry of Small Static Fields Used in External Beam Radiotherapy by the International Atomic Energy Agency
{c}
{tag=Work by International Atomic Energy Agency}
{title2=2017}
{title2=IAEA Technical Reports Series No. 483}

https://www-pub.iaea.org/MTCD/Publications/PDF/D483_web.pdf

Corporate author and publisher: International Atomic Energy Agency. The title page names IAEA and AAPM sponsorship; the copyright page states 2017 and printing in November 2017.

Physical detector-response locators: §3.1.4, printed p. 37, defines the volume-averaging correction through the point dose and spatially averaged dose in undisturbed water; equation (5) includes spatial weighting. Appendix I.2.3, printed pp. 145–150, equations (52)–(53), discusses measured lateral profiles, geometric weighting models and averaging corrections. These locators support the detector-response physics.