= Force on a pipe junction
{wiki}

The <force on a pipe junction> follows from vector <momentum conservation> for the fluid inside the junction. In steady flow, the sum of outward momentum fluxes minus inward momentum fluxes equals the external resultant on that fluid. A section with nearly uniform velocity contributes mass flow rate times its velocity vector, with the appropriate inlet or outlet sign.

Pressure also pushes on every cut section: with an outward normal $\mathbf n$, the pressure force on the control-volume fluid is $-pA\mathbf n$. Adding gravity and the unknown wall force gives a solvable balance once flow rates, directions and pressures are specified. The force of the fluid on the pipe is the opposite of the wall force on the fluid.

A right-angle bend redirects a jet even when inlet and outlet speed magnitudes agree. Its momentum vectors differ, so its support must carry a load. This is why scalar speed or energy balances alone cannot determine the mounting force.