Integrator reset (source code)

= Integrator reset

An \b[integrator reset] establishes the charge on an <integrating amplifier>'s feedback <capacitor> before the next measurement. Without it, the next output includes the previous <initial condition>, and repeated input pulses or <input offset voltage> can eventually cause <amplifier clipping>. Resetting makes consecutive measurement intervals comparable; it does not reconstruct a pulse already lost to <amplifier clipping>.

Consider an inverting <integrating amplifier> with the input held at zero during reset. Place an <analog switch> across its feedback <capacitor> $C$. In the approximation of a stable ideal <operational amplifier> maintaining a <virtual ground>, a closed switch with constant on-state <electrical resistance> $R_{\rm on}$ gives the <RC circuit> relation
$$
\frac{dv_o}{dt}=-\frac{v_o}{R_{\rm on}C},\qquad
v_o(t)=V_{\rm old}e^{-t/(R_{\rm on}C)}.
$$
This <exponential decay> gives an <integrator reset settling time> for residual magnitude at most $\varepsilon$:
$$
T_{\rm reset}\geq R_{\rm on}C\ln\!\frac{|V_{\rm old}|}{\varepsilon}
\quad\text{when }|V_{\rm old}|>\varepsilon.
$$
For stipulated values $C=10\,\mathrm{nF}$, $R_{\rm on}=10\,\mathrm{k\Omega}$ and $|V_{\rm old}|=0.50\,\mathrm V$, the reset time constant is $100\,\mathrm{\mu s}$. Reaching a residual of $1\,\mathrm{mV}$ requires \b[about $621\,\mathrm{\mu s}$] in this model. Actual amplifier drive, stability and recovery from overload can change the response. A switch's control delay also differs from the full circuit's <settling time>.<MT-088: Analog Switches and Multiplexers Basics>[pp11–13, Figures19–21: settling versus switching delay]{ref}

Opening the reset switch can itself disturb the initial condition. <Analog switch charge injection> transfers a small charge to the connected <capacitor>, producing a <reset charge-injection pedestal> of magnitude
$$
|\Delta v|=\frac{|Q_{\rm inj}|}{C}.
$$
For a stipulated $10\,\mathrm{pC}$ deposited on $10\,\mathrm{nF}$, this step is $1\,\mathrm{mV}$. Its sign depends on the circuit and charge direction. A longer reset suppresses the preceding exponential residual but need not suppress the new step created when the switch opens. Analog Devices illustrates this capacitive coupling mechanism and the resulting output step separately from retained-charge settling.<MT-088: Analog Switches and Multiplexers Basics>[pp9–10, Figures13–16]{ref}

A practical experiment repeats zero-input measurements with several reset durations and reads the output at the same delay after switch opening. A decreasing residual indicates incomplete discharge; a persistent offset can instead include <reset charge-injection pedestal>, <input offset voltage> and subsequent drift. Repeated readings help separate the reproducible offset from <noise>. The ACF2101 provides a concrete historical implementation: separate hold and reset controls disconnect the input and discharge the integration <capacitor>, and its datasheet shows the sequence of hold, integration and reset states.<ACF2101 Low Noise, Dual Switched Integrator datasheet>[p9, Modes of Operation, Hold and Reset Switches, Figures3–4; p3, Charge Transfer Errors]{ref}

The reset interval also creates <integrator reset dead time>: charge arriving while the circuit is being reset may not contribute to the next measured integral. Pulse timing relative to the reset therefore matters. A perfectly repeatable baseline alone does not establish that every input pulse was captured.