Magnetorotational instability (source code)

= Magnetorotational instability
{title2=MRI}
{wiki}

= MRI
{c}
{synonym}

The <magnetorotational instability> allows a weak <magnetic field> to destabilize some differentially rotating flows that are stable to axisymmetric hydrodynamic displacements. A useful picture connects two <fluid> elements by <magnetic tension>: the inner element loses <angular momentum> and moves inward, while the outer element gains <angular momentum> and moves outward. Decreasing angular <velocity> amplifies their separation. This makes the instability relevant to <angular momentum transport> in an <accretion disk>.

For a local, unstratified, incompressible ideal-MHD model with vertical <magnetic field> $B_z$, take an axisymmetric perturbation proportional to $e^{st+ikz}$. Let $v_A=|B_z|/\sqrt{\mu_0\rho}$ and $\kappa$ be the <radial epicyclic frequency>, with
$$
\kappa^2=4\Omega^2+\frac{d\Omega^2}{d\log R}.
$$
Eliminating the horizontal <velocity> and magnetic perturbations gives
$$
s^4+(\kappa^2+2k^2v_A^2)s^2
+k^2v_A^2\left(k^2v_A^2+\frac{d\Omega^2}{d\log R}\right)=0.
$$
For a hydrodynamically stable background with $\kappa^2>0$, a growing root exists exactly when
$$
0<k^2v_A^2<-\frac{d\Omega^2}{d\log R}.
$$
Indeed, the constant term is then negative, so the quadratic in $s^2$ has one positive root. If the constant term is nonnegative, both roots are nonpositive: their sum is negative and their discriminant is $\kappa^4+16\Omega^2k^2v_A^2$. The vertical-field local limit follows from the original linear analysis.<A Powerful Local Shear Instability in Weakly Magnetized Disks. I. Linear Analysis by Steven A. Balbus and John F. Hawley>[Sections 2.1–2.3, dispersion relation (2.9) and weak-field stability conditions]{ref}

In a <Keplerian disk>, the unstable interval is $0<k^2v_A^2<3\Omega^2$. Maximizing the positive root gives $k^2v_A^2=15\Omega^2/16$ and growth rate $s_{\max}=3\Omega/4$. Strong tension stabilizes shorter <wavelengths>. In a finite disk the unstable <wavelengths> must also fit the vertical domain; <magnetic diffusivity>, <viscosity> and nonideal magnetic coupling can modify or suppress them. Thus a negative angular-velocity gradient alone is not a universal sufficient condition for every magnetized flow. Linear growth also does not by itself specify the eventual turbulent <stress>.