Bearing end-stop engagement temperature

ID: bearing-end-stop-engagement-temperature

The bearing end-stop engagement temperature is the temperature state at which free relative expansion first exhausts the clearance to an axial stop. It must specify the initial setting and how both shaft and housing temperatures change. A non-locating bearing arrangement normally accommodates relative expansion; an exhausted travel limit changes the axial constraint.[ref]
For an illustrative common temperature increase , write free relative movement as
where is the assembly offset toward the stop. With positive remaining gap and , engagement occurs at
For hypothetical , and , . A0.10mm gap with no initial offset closes after50K common heating. Treating the housing as fixed would instead give16.67K, a different boundary-condition model.
An initial offset reduces the engagement increase to40K. With combined axial compliance , the engaged bearing thermal reaction slope is
At60K increase, the excess20K beyond engagement therefore gives320N of bearing thermal end-stop load in this linear quasistatic model.
If , common uniform heating does not change the relative gap in this model. If , heating moves away from the stated stop; cooling or another operating change can be relevant instead. Temperature gradients or independently heated components require their actual relative-displacement model rather than a universal scalar engagement temperature.