Inferring incident power from a transmitted plasma field

ID: inferring-incident-power-from-a-transmitted-plasma-field

For a downward transverse wave in an isotropic plasma, fixes the transmitted direction. Tangential phase matching gives . Continuity of tangential electric and magnetic fields then separates incident and reflected amplitudes. A measured transmitted electric amplitude alone cannot be identified with the incident one; mean power for peak phasors includes a factor of one half, and interface-normal flux includes a cosine.