Integer frame-count choice under a Raman saturation limit
ID: integer-frame-count-choice-under-a-raman-saturation-limit
Integer frame-count choice under a Raman saturation limit chooses the number of pump-on/off exposure pairs as well as their durations. More pairs incur more readout overhead; too few pairs can saturate before using the available wall-clock budget. Under the model of maximum-exposure constraint in paired Raman acquisition, for positive readout time and frame cap , each candidate integer with has usable live timeIts unused budget is . This wall-clock slack in saturation-limited Raman frame allocation is allowed: failure to consume the entire budget does not make a shorter acquisition physically impossible.
For each candidate, allocate with each total at most . Clip the unconstrained on total to , then evaluate . This solves the continuous subproblem; comparing the finitely many integer candidates solves the stated frame-count problem. Positive counts and no other costs make additional feasible live time beneficial.
In an original example, use , , , and . The relevant candidates areFour pairs are globally optimal in this model: one or two pairs use both states at their caps and improve as increases; three is evaluated explicitly; for every the unconstrained ratio is feasible and increases with . At four pairs the on/off totals are about and .
The primary Raman apparatus used 97 ms exposures to avoid saturation and 10 ms shuttered readout, motivating these stipulated example timings.[ref]
Femtosecond Broadband Stimulated Raman: A New Approach for High-Performance Vibrational Spectroscopy by David W. McCamant and others. Data Collection, exposure limit and on/off shutter sequence preceding equation 4
Actual frame choice can also be constrained by read noise, drift and minimum switching cadence. Such costs must be included before treating this shot-noise-only optimum as an experimental operating prescription. New to topics? Read the docs here!