Maser discovery experiment

ID: maser-discovery-experiment

Ammonia gas entered a vacuum chamber through fine channels; the selected beam entered a cavity with input and output waveguides.[ref] With external microwaves swept across a molecular resonance, the 1954 experiment read an increase in transmitted power; with sufficient beam emission, it sustained oscillation.[ref]
The 1955 readout mixed two maser signals with a local oscillator in a crystal detector, amplified them at an intermediate frequency, and combined them in a diode detector. An oscilloscope showed their beat frequency. Changing cavity tuning, source pressure or focuser field tested sensitivity; excessive detuning stopped oscillation.[ref] The beat tests relative frequency stability; it does not by itself establish an absolute frequency or an intrinsic linewidth independent of detector noise. Detuning also changes the field–molecule interaction, so the threshold model's constant cannot describe arbitrary tuning scans.

New to topics? Read the docs here!