A mercury barometer measures atmospheric pressure by balancing it against a vertical Mercury column. A tube closed at its upper end connects below to a mercury reservoir open to the atmosphere. If the gas pressure above the column is , hydrostatic equilibrium gives , where is the vertical separation of the two mercury surfaces.
The height measures a pressure difference; interpreting it requires the actual mercury mass density and local gravitational acceleration. Residual gas above the column, capillarity and temperature-dependent scale length can shift the reading.[ref]
Mercury Barometers and Manometers by W. G. Brombacher and others. §3.1, principle of measurement; §§6.4 and 7, vacuum and error sources
The mercury-barometer temperature correction treats density and scale expansion explicitly. Distinguishing the two liquid levels is essential: an upper-surface position alone is not always the full column height. New to topics? Read the docs here!