Solution

ID: past-exam-of-the-physics-2-paper-of-the-university-of-oxford/2021/11/b/solution

In the long-solenoid approximation, the internal magnetic flux density is uniform, , and the external magnetic field is negligible. This follows from the magnetostatic Ampère law applied to a rectangular loop running inside and outside the solenoid. Its number of turns is and its cross-sectional area is . Each turn links magnetic flux . Therefore the flux linkage is
Using the definition of self-inductance, , gives
This neglects end leakage and winding thickness and uses vacuum permeability for the air core.

New to topics? Read the docs here!