ID: past-exam-of-the-year-2-of-the-earth-sciences-geology-course-of-the-university-of-oxford/2024/paper-3/2/b/solution

For a wide horizontal Bouguer slab replacing surrounding basement, use the density contrast , not the absolute sediment density:
Take downward attraction as positive. The negative anomaly therefore requires . With , , and ,
so
This is the requested Bouguer slab approximation: a flat observation surface, laterally infinite constant-thickness material, uniform average geophysical density contrast, and a regional anomaly already removed. The actual basin in Figure 1 narrows downwards and is finite. For a fixed maximum thickness, finite width reduces the central anomaly magnitude, so this calculation can underestimate the true magnitude of the average geophysical density contrast. It does not establish a unique basement density without the geometrical assumption.