Small-signal response of a gapped magnetic core

ID: small-signal-response-of-a-gapped-magnetic-core

For a uniform core of path length , a narrow air gap , and winding turns, Ampère's circuital law gives when leakage and fringing are negligible. If a reversible branch has differential magnetic permeability , linearization gives . An offset in the operating branch changes the bias field, not this differential formula. For at the origin, .