Uniformly magnetized ellipsoid
ID: uniformly-magnetized-ellipsoid
For an ellipsoidal sample in a uniform applied magnetic field intensity along a principal axis, its uniform demagnetizing field is . The SI demagnetizing factor obeys . Linear magnetic susceptibility gives , hence . An axially slender prolate limit has , a sphere has , and a thin plate with field normal to it has . Thus belongs to the plate limit, not the slender axial-rod limit. A finite cylinder generally has nonuniform magnetization; an effective ellipsoidal factor is an approximation rather than an exact universal correction.