= Elementary charge
{title2=$e=1.602176634\times10^{-19}\,\mathrm C$}
{wiki}
The <elementary charge> is the positive magnitude $e$ of the <electron>'s <electric charge>, not the signed <electric charge> of the <electron> itself:
$$
q_{\mathrm{electron}}=-e,\qquad q_{\mathrm{proton}}=+e,\qquad e=1.602176634\times10^{-19}\,\mathrm C\quad\text{exactly in SI}.
$$
Since the 2019 revision of the <SI>, this numerical value defines the <ampere> together with the definition of the second; $1\,\mathrm C=1\,\mathrm{A\,s}$. Thus today's numerical exactness is a choice of units, whereas measured <electric charges> still have experimental uncertainty. An <oil drop experiment> can test <charge quantization> and the apparatus calibration; it does not supply a new uncertain defining value of $e$ in today's <SI>. https://www.bipm.org/documents/20126/41483022/SI-Brochure-9-EN.pdf[BIPM, The International System of Units, ninth edition, sections 2.2 and 2.3.1, the ampere]{ref}.
For ordinary isolated <chemical atoms>, <ions> and charged objects whose net <electric charge> is counted through <protons> and <electrons>, <charge quantization> gives $Q=ne$ with signed <integer> $n$. A neutral <chemical atom> that loses two <electrons> becomes an <ion> of <electric charge> $+2e$. A toy object with $10^9$ excess <electrons> has $Q=-0.1602176634\,\mathrm{nC}$. Conversely, the scale $1\,\mathrm{nC}/e\simeq6.24\times10^9$ explains why laboratory <electric charge> often looks continuous: billions of microscopic increments fit into a small macroscopic amount. Averaged <charge density> is a continuum description, not a claim that each particle has an arbitrarily divisible <electric charge>.
The ordinary-matter qualifier matters. In the <Standard Model>, <quarks> have <electric charges> $+2e/3$ or $-e/3$, and <antiquarks> have the opposite signs. <Confinement> means these are constituents of <hadrons>, not isolated fractionally charged particles collected by an <oil drop experiment>. The usual valence <quark> sums give $2(2e/3)-e/3=e$ for a <proton> and $2e/3-2(e/3)=0$ for a <neutron>. Thus <elementary charge> should not be defined as the smallest nonzero <electric charge> of every constituent in particle theory. https://pdg.lbl.gov/2022/reviews/rpp2022-rev-quark-model.pdf[Amsler, DeGrand and Krusche, Particle Data Group, Quark Model, sections 15.1–15.2 and table 15.1]{ref}.
The beautiful experimental idea behind the <oil drop experiment> is to determine a microscopic <electric charge> by watching a visible carrier move. In his 1913 paper, Millikan timed the descent and electrically driven ascent of individual oil drops, repeatedly changing a drop's <electric charge> through capture of air <ions>. His apparatus used parallel plates separated by $16\,\mathrm{mm}$, a roughly $5300\,\mathrm V$ source, and an optical scale to measure travel distances. He reported multiple relationships among a given drop's inferred <electric charges>. He also found that uncorrected <Stokes's law> gave a size-dependent inferred elementary unit, and introduced a pressure-dependent slip correction. These were measured relationships with calibration and model uncertainties, not exact readings of today's defined $e$. https://grundpraktikum.physik.uni-saarland.de/gpalt/Anleitungen/Ergaenzungen/Versuche/Millikan/Millikan%20-%20On%20the%20Elementary%20Electrical%20Charge%20and%20the%20Avogadro%20Constant.pdf[R. A. Millikan, On the Elementary Electrical Charge and the Avogadro Constant, Physical Review 2 (1913), 109–143, especially pp. 109–112 and 115–116]{ref}.
\Image[/electric-charge-oil-drop-forces.png]
{title=<Oil drop experiment>: apparatus and terminal <force> balances}
{description=Original schematic for a negative drop between a positive upper plate and negative lower plate. The <electric field> points downward and the <electric force> upward. <Drag> opposes each direction of motion; <buoyancy> remains upward. Geometry and arrow lengths are not to scale, and no historical measurements are recreated.}
{source=electric-charge-oil-drop-forces.py}
A modern instructional implementation sprays low-volatility oil of known <density> through a plate aperture, illuminates the drops, and follows one through a calibrated optical scale. Measure the plate spacing $d$, <electric potential difference> $V$, air <temperature> and <pressure>. Time a fixed distance $L$ with the <electric field> off to get a terminal falling speed $v_f=L/t_f$. Then choose the field polarity to drive the same drop upward and measure $v_r=L/t_r$. Repeat timings at a fixed <electric charge>, and compare before and after an ion-capture event. The same drop is especially useful because its <radius> and <mass> need not be inferred anew for each charge state. https://cdn.pasco.com/product_document/Millikan-Oil-Drop-Manual-AP-8210B.pdf[PASCO, Millikan Oil Drop Apparatus AP-8210B manual, introduction, theory and experimental procedure]{ref}.
Here is the leading continuum model, retaining <buoyancy>. Assume a drop shaped as a <sphere> of <radius> $a$, oil and air <densities> $\rho_o$ and $\rho_a$, air <dynamic viscosity> $\eta$, and <gravitational acceleration> $g$. Define the downward effective weight $W$ and positive <linear drag> coefficient $k$ by
$$
W=\frac{4\pi a^3}{3}(\rho_o-\rho_a)g,\qquad k=6\pi\eta a,\qquad E\simeq\frac{|V|}{d}.
$$
At <terminal velocity>, the net <force> vanishes. Falling with no <electric field>, the upward <drag force> balances weight minus <buoyancy>. Rising with the <electric force> upward, the <drag force> reverses and joins the downward effective weight:
$$
kv_f=W,\qquad |q|E=W+kv_r=k(v_f+v_r).
$$
Consequently the uncorrected estimates are
$$
a=\sqrt{\frac{9\eta v_f}{2(\rho_o-\rho_a)g}},\qquad |q|=\frac{6\pi\eta a(v_f+v_r)d}{|V|}.
$$
The observed direction of response, with known field polarity, supplies the sign of $q$. A suspended drop gives the alternative balance $|q|E=W$, but it still requires a determination of $W$: balancing a drop alone does not determine its <electric charge>.
For an explicitly invented continuum example, stipulate $a=1\,\mu\mathrm m$, $\rho_o=900\,\mathrm{kg\,m^{-3}}$, $\rho_a=1.2\,\mathrm{kg\,m^{-3}}$, $\eta=1.8\times10^{-5}\,\mathrm{Pa\,s}$, $g=9.81\,\mathrm{m\,s^{-2}}$, $q=-5e$ and a downward $E=10^5\,\mathrm{V\,m^{-1}}$. The balances predict $W\simeq3.69\times10^{-14}\,\mathrm N$, $v_f\simeq0.109\,\mathrm{mm\,s^{-1}}$ and $v_r\simeq0.127\,\mathrm{mm\,s^{-1}}$. Substituting those speeds recovers $|q|=5e$ within rounding. This checks the algebra; it is not a precision prediction for real micrometre drops, which need a slip correction.
The inference has two distinct parts. Compare inferred <electric charges> or charge changes with a common unit, seeking $q_i\simeq n_i e$ within uncertainty, rather than demanding exact ratios of rounded measurements. Then establish the absolute scale through <electric field>, <density>, <dynamic viscosity> and distance/time calibration. If the observed steps are all even multiples, their common spacing alone cannot exclude an unobserved smaller unit. Air motion, evaporation and mistimed crossings can alter inferred <electric charge> without an ion-capture event. Small <Reynolds number> supports <Stokes's law>, but does not by itself justify its no-slip continuum coefficient: a significant ratio of air <mean free path> to drop <radius> requires a slip correction. Millikan's comparison of different drop sizes and pressures addressed that systematic limitation; the modern PASCO manual also includes the correction. Agreement supports <charge quantization> for the observed carriers within experimental resolution, rather than proving a universal statement about every possible particle.
Multiplying $e$ by the <Avogadro constant> gives the <Faraday constant>, $F=N_Ae$, the <electric charge> per <mole> of singly charged carriers. This connects counting individual <electric charges> with bulk <electrochemistry>. https://physics.nist.gov/cuu/pdf/wall_2022.pdf[NIST, CODATA 2022 defining constants and Faraday constant]{ref}.
Back to article page