The elementary charge is the positive magnitude of the electron's electric charge, not the signed electric charge of the electron itself:Since the 2019 revision of the SI, this numerical value defines the ampere together with the definition of the second; . Thus today's numerical exactness is a choice of units, whereas measured electric charges still have experimental uncertainty. An oil drop experiment can test charge quantization and the apparatus calibration; it does not supply a new uncertain defining value of in today's SI. [ref]
https://www.bipm.org/documents/20126/41483022/SI-Brochure-9-EN.pdf. BIPM, The International System of Units, ninth edition, sections 2.2 and 2.3.1, the ampere
.For ordinary isolated chemical atoms, ions and charged objects whose net electric charge is counted through protons and electrons, charge quantization gives with signed integer . A neutral chemical atom that loses two electrons becomes an ion of electric charge . A toy object with excess electrons has . Conversely, the scale explains why laboratory electric charge often looks continuous: billions of microscopic increments fit into a small macroscopic amount. Averaged charge density is a continuum description, not a claim that each particle has an arbitrarily divisible electric charge.
The ordinary-matter qualifier matters. In the Standard Model, quarks have electric charges or , and antiquarks have the opposite signs. Confinement means these are constituents of hadrons, not isolated fractionally charged particles collected by an oil drop experiment. The usual valence quark sums give for a proton and for a neutron. Thus elementary charge should not be defined as the smallest nonzero electric charge of every constituent in particle theory. [ref]
https://pdg.lbl.gov/2022/reviews/rpp2022-rev-quark-model.pdf. Amsler, DeGrand and Krusche, Particle Data Group, Quark Model, sections 15.1–15.2 and table 15.1
.The beautiful experimental idea behind the oil drop experiment is to determine a microscopic electric charge by watching a visible carrier move. In his 1913 paper, Millikan timed the descent and electrically driven ascent of individual oil drops, repeatedly changing a drop's electric charge through capture of air ions. His apparatus used parallel plates separated by , a roughly source, and an optical scale to measure travel distances. He reported multiple relationships among a given drop's inferred electric charges. He also found that uncorrected Stokes's law gave a size-dependent inferred elementary unit, and introduced a pressure-dependent slip correction. These were measured relationships with calibration and model uncertainties, not exact readings of today's defined . [ref]
https://grundpraktikum.physik.uni-saarland.de/gpalt/Anleitungen/Ergaenzungen/Versuche/Millikan/Millikan%20-%20On%20the%20Elementary%20Electrical%20Charge%20and%20the%20Avogadro%20Constant.pdf. R. A. Millikan, On the Elementary Electrical Charge and the Avogadro Constant, Physical Review 2 (1913), 109–143, especially pp. 109–112 and 115–116
.A modern instructional implementation sprays low-volatility oil of known density through a plate aperture, illuminates the drops, and follows one through a calibrated optical scale. Measure the plate spacing , electric potential difference , air temperature and pressure. Time a fixed distance with the electric field off to get a terminal falling speed . Then choose the field polarity to drive the same drop upward and measure . Repeat timings at a fixed electric charge, and compare before and after an ion-capture event. The same drop is especially useful because its radius and mass need not be inferred anew for each charge state. [ref]
https://cdn.pasco.com/product_document/Millikan-Oil-Drop-Manual-AP-8210B.pdf. PASCO, Millikan Oil Drop Apparatus AP-8210B manual, introduction, theory and experimental procedure
.Here is the leading continuum model, retaining buoyancy. Assume a drop shaped as a sphere of radius , oil and air densities and , air dynamic viscosity , and gravitational acceleration . Define the downward effective weight and positive linear drag coefficient byAt terminal velocity, the net force vanishes. Falling with no electric field, the upward drag force balances weight minus buoyancy. Rising with the electric force upward, the drag force reverses and joins the downward effective weight:Consequently the uncorrected estimates areThe observed direction of response, with known field polarity, supplies the sign of . A suspended drop gives the alternative balance , but it still requires a determination of : balancing a drop alone does not determine its electric charge.
For an explicitly invented continuum example, stipulate , , , , , and a downward . The balances predict , and . Substituting those speeds recovers within rounding. This checks the algebra; it is not a precision prediction for real micrometre drops, which need a slip correction.
The inference has two distinct parts. Compare inferred electric charges or charge changes with a common unit, seeking within uncertainty, rather than demanding exact ratios of rounded measurements. Then establish the absolute scale through electric field, density, dynamic viscosity and distance/time calibration. If the observed steps are all even multiples, their common spacing alone cannot exclude an unobserved smaller unit. Air motion, evaporation and mistimed crossings can alter inferred electric charge without an ion-capture event. Small Reynolds number supports Stokes's law, but does not by itself justify its no-slip continuum coefficient: a significant ratio of air mean free path to drop radius requires a slip correction. Millikan's comparison of different drop sizes and pressures addressed that systematic limitation; the modern PASCO manual also includes the correction. Agreement supports charge quantization for the observed carriers within experimental resolution, rather than proving a universal statement about every possible particle.
Multiplying by the Avogadro constant gives the Faraday constant, , the electric charge per mole of singly charged carriers. This connects counting individual electric charges with bulk electrochemistry. [ref]
https://physics.nist.gov/cuu/pdf/wall_2022.pdf. NIST, CODATA 2022 defining constants and Faraday constant
.The oil drop experiment infers an oil drop's electric charge from its motion under gravity, buoyancy, drag and a calibrated electric field. Repeated changes of a single drop's electric charge reveal discrete steps; see the model, experimental procedure and limitations in elementary charge.
Robert Andrews Millikan's 1911 protocol alternated electrically driven ascent with timed descent after short-circuiting the plates; a changed ascent speed signalled ion capture.[ref]
His 1913 refinements checked voltage before and after runs, calibrated optical distance and the clock, compared independent air-dynamic viscosity measurements, and varied pressure to test slip.[ref]
On the Elementary Electrical Charge and the Avogadro Constant by Robert Andrews Millikan. pp. 112–118
His 1924 lecture describes suppressing convection, switching the electric field, neutralizing drops, and reproducing smallest observed electrical speed increments.[ref]The Electron and the Light-Quant from the Experimental Point of View by Robert Andrews Millikan. Nobel Lectures, Physics 1922–1941; pp. 56–60
Harvey Fletcher's posthumous account recalls building the first oil apparatus and measuring with Robert Andrews Millikan; priority for suggesting oil remains uncertain.[ref]
To interpret the readout, keep one drop and one electric field polarity. Let be its signed upward terminal velocity in charge state , and let be its field-off falling speed. Use the linear drag coefficient already defined in elementary charge, with any required gas slip correction to Stokes drag included. Provided the drop's radius, surrounding air and electric field remain fixed, its electrical speed increment isThese relations apply while the electric force points upward in every state. A drop may still descend, with , when that force is too weak to support it. A held drop has and therefore , rather than zero electrical response. A neutral drop has : its signed terminal velocity agrees with field-off descent. Thus neither raw upward speed nor the ability to hold a drop is itself a count of electrons.
The ratios cancel a fixed , even if its value is poorly known. This is why relative charge quantization and absolute measurement calibration are different questions. A changed field-off warns that evaporation, air motion or another change has spoiled comparison of charge states. A stable is useful evidence but cannot exclude every compensating change. Repeat field-off checks around a proposed jump, allow the terminal velocity under linear drag to settle after switching, and propagate measurement uncertainty in both the field-on and field-off readings. Reusing a single estimate of gives the different a shared covariance.
Simulated repeated electric charge states and resolved charge changes of one drop
. Original chosen noisy readings in an arbitrary reference electric charge , with four state means and their stipulated standard uncertainties. These are a simulation, not measurements by Robert Andrews Millikan or Harvey Fletcher. Acquisition order is not elapsed time; connecting lines only group observations made in the same state. Details.An integer pattern must survive the stated measurement uncertainty. For an original simulated example, choose a reference electric charge , define , and stipulate state meansHere each is an independent standard uncertainty of a state mean, before shared calibration effects. The generator constructs repeated noisy observations with these means; the numbers are deliberately chosen, not historical data. There is no conversion of to coulombs and no measured value of the elementary charge in this example.
For a candidate spacing in units of and proposed integers , use weighted least squares:The last two expressions follow by differentiating the quadratic in and propagating the independent errors. They are conditional on fixed, correct integer assignments and the stated error model. They do not include uncertainty from choosing those assignments. For , they give , , and . Such a small residual is compatible with this chosen error scale; it is not evidence that the errors vanish. A chi-squared distribution interpretation additionally needs the appropriate normal distribution error model and allowance for the fitted parameter; searching many assignments changes that interpretation.
Finite noisy electric charges fit a candidate unit and its subdivisions
. Original calculation for the simulated state means above. Horizontal bars show one standard uncertainty. Both spacings and have exactly the same fitted locations and residuals when the integer labels double. The lower curve minimizes over integers separately at every candidate spacing; a low residual alone cannot identify the elementary charge. Details.The obstruction is identifiability: replacing by for any positive integer leaves every predicted reading unchanged. In particular, an -spaced pattern also fits an lattice using even indices. Even the coarsest well-fitting spacing need not be the physical unit: a dataset containing only even charge states can have twice that unit. Worse, if arbitrarily fine spacings and unrestricted integers are allowed, rounding each givesConsequently a finite fit cannot prove a minimal transferable electric charge. Reproducible smallest observed jumps supply additional evidence; interpreting them as single-carrier transfers requires independent physical support. One visibly abrupt transition could contain several unresolved transfers. In the simulation the successive differences are , , and , each with standard uncertainty . These support changes near conditional on that unit; they equally support units of . Neighboring differences share a state reading and are therefore correlated, even though the state means were stipulated independent.
A shared scale error can preserve every apparent integer relation. To first order, an independent fractional scale standard uncertainty adds to the covariance matrix of the . For the simulation, stipulating changes the conditional uncertainty of to approximately , despite the same residual pattern. Repeating timings cannot average away this common scale contribution. In the uncorrected continuum model in elementary charge, holding the other measured inputs fixed gives , so a small fractional error in air dynamic viscosity causes times that fractional error in inferred electric charge. The gas slip correction to Stokes drag requires its own propagation. Pattern agreement, drop-stability controls and absolute measurement calibration together make the inference persuasive within resolution.
Articles by others on the same topic
The elementary charge is the smallest unit of electric charge that is considered to be indivisible in classical physics. It is denoted by the symbol \( e \) and has a value of approximately \( 1.602 \times 10^{-19} \) coulombs. This charge is carried by a single proton, which has a positive charge of \( +e \), while an electron, which has a negative charge, carries a charge of \( -e \).
Experiments to measure it:
The 2019 redefinition of the SI base units defines it precisely and uses it as a measure of charge: en.wikipedia.org/wiki/2019_redefinition_of_the_SI_base_units#Ampere


