Inspiratory capacity 2026-11-05
Inspiratory capacity, IC, is the maximum volume that can be inhaled from the end of a quiet expiration to maximal inspiration. Its lower reference is functional residual capacity, and its upper reference is total lung capacity:The last expression combines tidal volume with inspiratory reserve volume.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Definitions and subdivisions of lung volume; Figure 1
For stipulated total lung capacity 6.0 L and functional residual capacity 2.5 L, IC is 3.5 L. If tidal volume is 0.5 L, the corresponding inspiratory reserve volume is 3.0 L. The two descriptions use the same maximum inspiratory endpoint but different starting points.
The starting point is essential when interpreting a change. In an original comparison, keep total lung capacity at 6.0 L while moving the quiet end-expiratory level from 2.5 to 3.2 L. IC falls from 3.5 to 2.8 L, although the maximum inspiratory volume has not changed. Thus a lower inspiratory capacity need not imply a lower total lung capacity; an independently specified baseline is required to distinguish the possibilities.
Inhalation through a volume-measuring apparatus can determine an inspiratory increment without directly measuring the gas already present in the lungs. A stable starting level and complete endpoint connect that increment to the defined capacity. The technical standard therefore links capacity maneuvers with an identified FRC-level measurement.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Measurement of FRC and linked capacity maneuvers
The values in the example illustrate endpoint bookkeeping rather than reference limits for a particular person. Inspiratory reserve volume 2026-11-05
Inspiratory reserve volume, IRV, is the additional gas that can be inhaled after the end of an ordinary tidal inspiration, up to maximal inspiration. It is the portion of inspiratory capacity beyond tidal volume:The starting point is end-inspiration, rather than the quiet end-expiratory level used for inspiratory capacity.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Definitions and subdivisions of lung volume; Figure 1
For a stipulated total lung capacity of 6.0 L, functional residual capacity 2.5 L and tidal volume 0.5 L, end-tidal inspiration reaches 3.0 L and leaves IRV 3.0 L. The full 3.5 L inspiratory capacity includes both the ordinary 0.5 L breath and this additional excursion.
A deeper ordinary breath changes the subdivision even if the absolute endpoints remain fixed. Holding functional residual capacity at 2.5 L and total lung capacity at 6.0 L while increasing tidal volume to 1.0 L reduces IRV to 2.5 L. Thus a change in inspiratory reserve volume need not imply that maximum inspiratory volume changed.
The name describes an available volume increment, not a separate anatomical compartment sealed off from tidal gas. In the ideal volume ledger, boundaries between subdivisions are reference states on the same gas-volume coordinate. A useful measurement consequently states the ordinary breathing level and the maximum endpoint, rather than interpreting IRV independently of the preceding breath.
Total lung capacity 2026-11-05
Total lung capacity, TLC, is the volume of gas in the lungs after maximal inspiration. It combines residual lung volume with vital capacity, or equivalently functional residual capacity with inspiratory capacity:The equivalent subdivision is , using expiratory reserve volume, tidal volume and inspiratory reserve volume.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Definitions and subdivisions of lung volume; Figure 1
A constructed example assigns 1.2 L to residual lung volume, 1.0 L to expiratory reserve volume, 0.5 L to tidal volume and 3.3 L to inspiratory reserve volume. Their sum gives TLC 6.0 L. The vital capacity is 4.8 L, functional residual capacity is 2.2 L, and inspiratory capacity is 3.8 L. Each identity gives the same total because the compartments share consistent endpoints.
A spirometry trace alone measures changes at the mouth; it does not establish the volume remaining after complete expiration. Adding an arbitrary constant to the entire gas-volume trace leaves every observed inhaled and exhaled increment unchanged. An independent estimate of residual lung volume or functional residual capacity is therefore needed to fix that offset. The measurement standard obtains capacities by combining an FRC measurement with linked volume maneuvers.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Background and purpose; Measurement of FRC
This distinction also explains why vital capacity and total lung capacity are not interchangeable descriptors. Two hypothetical systems can both have a 4 L vital capacity, while having residual lung volume 1 and 2 L respectively. Their total capacities are then 5 and 6 L. The arithmetic separates the amount that can be exchanged during the maneuver from the amount present at full inspiration.
Vital capacity 2026-11-05
Vital capacity, VC, is the volume change between maximal inspiration and maximal expiration. It is the exchangeable difference between total lung capacity and residual lung volume:The sum uses inspiratory reserve volume, tidal volume and expiratory reserve volume.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Definitions and subdivisions of lung volume; Figure 1
A constructed volume record with maximum 6.0 L and minimum 1.4 L gives VC 4.6 L. Subdivisions 3.0 L, 0.5 L and 1.1 L give the same result. Those increments partition the full excursion; none includes the 1.4 L that remains after maximal expiration.
Forced vital capacity names a specific forceful expiratory maneuver. The broader vital capacity can also be measured during a relaxed expiration or inspiration. The maneuver and completeness of its endpoints matter when comparing measurements.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Definitions and subdivisions of lung volume, inspiratory VC, expiratory VC and FVC
[ref]Standardization of Spirometry 2019 Update by Brian L. Graham and others. FVC Maneuver; end-of-forced-expiration considerations
A spirometry trace records volume change, so the same VC can arise at different absolute lung-gas levels. A second stipulated record spanning 7.0 to 2.4 L also gives 4.6 L. Adding a common offset to every point leaves VC unchanged. This is why a precise vital capacity measurement alone cannot determine residual lung volume or total lung capacity.