Covariance-consistent rescaling of whitened spectral coordinates changes measurement units or mixes coordinates while transforming their noise model at the same time. If an invertible matrix maps a spectral vector to , then
The covariance follows directly from the expectation of the transformed error outer product. For positive-definite ,
Thus the inverse-covariance inner product, its norms and the resulting whitened angle are invariant. Invariance of noise-whitened spectral angles to the whitening factor establishes the related freedom to rotate the fully whitened coordinates.
For an original example, let , and . Their noise-whitened angle has cosine , or angle about . Converting only the first raw coordinate's numerical units by a factor of 1000 gives and . Using that transformed covariance keeps the cosine exactly .
If the shapes are rescaled but the old covariance is mistakenly retained, the calculated cosine becomes approximately , suggesting an angle only about . A unit conversion would then appear to destroy the separation between signal and nuisance. That apparent change comes from inconsistent uncertainty accounting.
For any full whitening factor , the transformed factor satisfies and gives . The pinned SciPy documentation describes whitening and demonstrates a near-identity covariance after transformation.[ref] Measurement propagation likewise retains all covariance terms under a linear transformation.[ref]
The invertibility condition matters. Noninvertible spectral compression versus a coordinate change can discard information and need not preserve these angles. A transformation estimated from the same noisy observations also brings estimation uncertainty beyond the fixed-matrix identity proved here.
The noise-whitened angle between spectral signal and nuisance shapes measures their separation in units of measurement noise rather than raw plotting units. For nonzero shapes and a positive-definite covariance , choose a square whitening transformation with . The angle is
It is the ordinary Euclidean angle after whitening. Both parallel and antiparallel shapes are indistinguishable up to an unknown nuisance amplitude; the precision penalty depends on , as in noise penalty from nearly parallel signal and reference shapes.
For an original example, take raw shapes , and . The plotted shapes are orthogonal, but whitening gives and . Thus and . The second channel, which separates their signs, is noisy. Rejecting the nuisance multiplies the optimum variance by , or standard uncertainty by .
The invariance of noise-whitened spectral angles to the whitening factor follows from . Different valid square whitening factors can rotate the whitened coordinates without changing the angle. Likewise an invertible change of measurement units transforms both shapes and covariance, leaving the inverse-covariance expression unchanged. Rescaling only the displayed curves while leaving their noise model fixed is a different operation.
The covariance must describe the actual measured channels and shared errors, using the full propagation rule.[ref] If is singular, first restrict to its physically allowed range; an unrestricted inverse whitening factor does not exist.
The primary stimulated-Raman experiment described systematic spectral noise and subtraction of a pure-solvent reference.[ref] The angle above assesses which desired patterns remain distinguishable after such nuisance rejection under a stated covariance. It does not establish that an estimated reference shape or noise model is itself accurate.