Two source scales obtained from dimensional analysis are
The jet length measures how far source momentum remains important relative to buoyancy-generated momentum. The source-volume length of a turbulent plume measures how far imposed source volume remains important relative to entrained volume. Numerical constants and entrainment coefficient factors depend on the chosen normalization. From the equations here the useful exact volume-growth scale is ; the pure-similarity height whose flux equals is . A momentum crossover likewise contains a factor of order . The source radius is another useful geometrical combination, but it does not replace the two buoyancy/source crossover comparisons.
Integrate the differential relation from part (a) with finite source values:
Define
This plume flux-balance invariant rearranges to
Use it to express , and substitute into . The coefficient satisfies , giving
With positive source fluxes, . For the source has excess momentum relative to pure plume balance, so it is a momentum-dominated forced plume. For it is already in pure plume balance, and the exact solution is the pure similarity translated to a finite plume virtual origin. For the source has deficient momentum relative to its buoyancy and volume fluxes, a lazy plume. Here “forced” in the broad sense merely means finite source fluxes; this sign classification distinguishes its jet-like and lazy branches. At large height, finite vanishes and every positive branch approaches pure plume balance.