An acquisition duration from a power-law tail-energy tolerance extends a measurement until the validated envelope's unrecorded energy is below a chosen tolerance. For the model in power-law tail from a decaying rate envelope, with ,
The parent article integrates this envelope and inverts the tolerance. Writing , its positive-duration requirement is when ; otherwise no additional duration is required.
In applying the rule, uncertainty in the exponent can dominate the result. With fixed and , differentiating the active branch gives
The required duration decreases with a larger exponent. For a guaranteed parameter range, a validated lower bound on a power-law tail exponent is therefore more useful than its best-fit value alone. Since decreases with for every , using the smallest allowed exponent bounds the entire tail, not just one selected sample.
For an original design example, let , and . A nominal exponent gives initial allowance , and . If the validated exponent range is instead , its slowest permitted tail has initial allowance and requires . The nominal duration does not guarantee the tolerance over that range. Upper bounds on and can likewise be used conservatively because increasing either raises the envelope pointwise.
If the allowed exponents reach one or below, these envelope assumptions alone no longer supply a finite all-time energy guarantee. This is a limitation of the bound, not proof that the actual pulse has infinite energy. The model must also hold throughout the unobserved interval: later pulses, persistent backgrounds or an electrical detector tail misidentified as optical power can invalidate it. NIST's independent receiver-response measurement illustrates this last experimental distinction.[ref] The power-law examples are original conditional models, not observed decay laws attributed to that apparatus.
Future-domain validity of a fitted power-law optical envelope means that the bound applies throughout the unobserved future interval where its integral is used, rather than merely matching a recorded waveform. The validated lower bound on a power-law tail exponent supplies a sufficient differential condition for such a bound. Agreement on a finite observation window alone does not establish it.
A concrete counterexample uses a fitted profile observed only for . Choose a later time and define an additional pulse
Both and are nonnegative and continuously differentiable, and they agree exactly on the recorded interval. Yet the unobserved extra energy is
Thus nonnegativity, this degree of smoothness and even a perfect finite-window fit cannot exclude an arbitrarily large later contribution.
For an original example, take , and . The fitted profile predicts remaining energy , below a tolerance. Put the later pulse at with width and peak . It adds , although all recorded data are unchanged. This unobserved delayed-pulse counterexample to a fitted tail bound violates the claimed missed-energy tolerance without altering the fit quality.
To use the envelope as a guarantee, state the physical assumptions that exclude such later input, justify the rate bound over the required future interval, or limit the claim to the interval actually validated. Recording a longer finite window improves evidence but does not alone supply an all-future theorem under only the assumptions used in this counterexample.
The waveform must also represent optical power rather than detector response. NIST's primary pulse calibration separately characterized the detector/cable/oscilloscope chain with a short optical input.[ref] Correcting the receiver is necessary for interpreting the trace, but it does not rule out the additional source pulse constructed here. The example is a mathematical comparison, not a reported failure of that apparatus.