Gas chromatography Updated +Created
This technique is crazy! It allows to both:
  • separate gaseous mixtures
  • identify gaseous compounds
You actually see discrete peaks at different minute counts on the other end.
It is based on how much the gas interacts with the column.
Detection is usually done burning the sample to ionize it when it comes out, and then you measure the current produced.
The procedure remind you a bit of gel electrophoresis, except that it is in gaseous phase.
Video 1.
Gas chromatography by Quick Biochemistry Basics (2019)
Source.
Video 2.
How I invented the electron capture detector interview with James Lovelock by Web of Stories (2001)
Source. He mentions how scientists had to make their own tools during the 40s/60s. Then how gas chromatography was invented at the National Institute for Medical Research and gained a Nobel Prize. Lovelock came in improving the detection part of things.
PCR verification with gel electrophoresis Updated +Created
Biology experiments are hard, and so they go wrong, a lot.
For this reason, it is wise to verify that certain steps are correct whenever possible.
And so this is the first thing we did on the second day!
Gel electrophoresis separates molecules by their charge-to-mass ratio. It is one of those ultra common lab procedures!
This allows us to determine how long are the DNA fragments present in our solution.
Since we know that we amplified the 16S regions which we know the rough size of (there might be a bit of variability across species, but not that much), we were expecting to see a big band at that size.
And that is exactly what we saw!
First we had to prepare the gel, put the gel comb, and pipette the samples into wells present in the gel:
Figure 1.
Gel electrophoresis insert comb.
Source.
Figure 2.
Gel electrophoresis top view with wells visible.
Source.
Figure 3.
Gel electrophoresis pipette sample into wells.
Source.
To see the DNA, we added ethidium bromide to the samples, which is a substance that that both binds to DNA and is fluorescent.
Because it interacts heavily with DNA, ethidium bromide is a mutagen, and the biology people sure did treat the dedicated electrophoresis bench area with respect! Figure 4. "Gel electrophoresis dedicated bench area to prevent ethidium bromide contamination.".
Figure 4.
Gel electrophoresis dedicated bench area to prevent ethidium bromide contamination.
Source.
Figure 5.
Gel electrophoresis dedicated waste bin for centrifuge tubes and pipette tips contaminated with ethidium bromide.
Source.
The UV transilluminator we used to shoot UV light into the gel was the Fisher Scientific UVP LM-26E Benchtop 2UV Transilluminator. The fluorescent substance then emitted a light we can see.
As barely seen at Figure 8. "Fischer Scientific UVP LM-26E Benchtop 2UV Transilluminator illuminated gel." due to bad photo quality due to lack of light, there is one strong green line, which compared to the ladder matches our expected 16S length. What we saw it with the naked eyes was very clear however.
Figure 6.
Fischer Scientific UVP LM-26E Benchtop 2UV Transilluminator
. Source.
Figure 7.
Fischer Scientific UVP LM-26E Benchtop 2UV Transilluminator loading gel.
Source.
Figure 8.
Fischer Scientific UVP LM-26E Benchtop 2UV Transilluminator illuminated gel.