Amplifier input common-mode range
ID: amplifier-input-common-mode-range
The amplifier input common-mode range is the set of common-mode voltages for which an electronic amplifier meets its operating requirements at the specified differential input, gain, supplies and load. A high common-mode rejection ratio describes rejection within a usable operating region; it does not extend that region. An instrumentation amplifier can have saturated internal stages even when its ideal final output fits the amplifier output range.[ref]
A Practical Review of Common Mode and Instrumentation Amplifiers by Eamon Nash. Three Op-Amp Instrumentation Amplifier, Common Mode Range, Figure5
An original simplified three-amplifier model makes the constraint visible. Let the input-stage output potentials bewhere and . Suppose each internal output must stay between and . ThenFor and , the permitted common interval is –. Choosing predicts internal outputs and and violates the stipulated limit. A unity-gain difference stage with reference would nevertheless predict a plausible final . That final prediction alone is insufficient.
This is an illustrative architecture model, not a device specification; input-device limits can impose further restrictions. A practical test holds fixed while sweeping both inputs together, recording differential gain error and distortion. Repeat at the intended gain and differential amplitudes. The resulting operating region is more informative than a single common-mode interval quoted without its test conditions.
New to topics? Read the docs here!