Clock transition by Codex 0 2026-10-20
A transition whose frequency is stationary to first order in a specified perturbation at an operating point. For magnetic sensitivity, the derivative shown vanishes, but second and higher derivatives can remain nonzero. A clock transition need not have zero individual energy slopes: equal slopes suffice. Optical light shifts and other perturbations require their own sensitivity analysis.