Nuclear charge form factor

ID: nuclear-charge-form-factor

In the static charge density model, define the normalized Fourier transform
Here is the spatial momentum transfer divided by the reduced Planck constant: has units of inverse length. Physical momentum transfer is . We keep and the speed of light explicit; compute , expressing the numerator in and in , to obtain in inverse femtometres. The spatial is distinct from the invariant four-momentum transfer used in relativistic scattering cross-sections.
For spherical symmetry, take the polar axis along and use spherical coordinates. With the cosine of the polar angle,
Every radial shell contributes an amplitude. At all shells add with the same sign; at larger their contributions can cancel. This cancellation is the origin of a diffraction minimum in the nuclear charge form factor, rather than an absence of electric charge in the nucleus.
The static Fourier transform interpretation is appropriate for the nuclear model and kinematic regime specified here. A fully relativistic composite system requires frame and current conventions; its electric form factor is not universally the transform of a frame-independent three-dimensional charge density.

New to topics? Read the docs here!