Reflection from a layered SH impedance

ID: reflection-from-a-layered-sh-impedance

Set the lower half-space load to using the causal vertical wavenumber branch, which excludes a wave arriving from depth infinity. Apply the uniform-layer SH impedance update upwards through every layer, keeping particle velocity and traction continuous. For upper half-space impedance , incident velocity and reflected velocity , the top values are and . Their ratio gives the displayed reflection coefficient, incorporating every underlying interface and multiple reflection.