Repeated-timing uncertainty in a pendulum gravity measurement

ID: repeated-timing-uncertainty-in-a-pendulum-gravity-measurement

For simple pendulum oscillation period in the small-angle approximation, . If the length measurement and identically precise timing measurements have independent errors, the timing sample mean has standard error . Propagation of uncertainty gives the title formula. A target fractional standard uncertainty requires , rounded upward to an integer. No amount of repeated timing can beat the floor without improving the length measurement; correlated errors or a timing systematic error require a different model.