Halfdan Ihlen 2026-11-05
Halfdan Ihlen was a Norwegian cardiologist who developed cardiac ultrasound research and diagnostic facilities at Rikshospitalet. A primary memorial by his colleagues records his specialist qualification in internal medicine and cardiology in 1982 and his later leadership of an ultrasound laboratory and appointment as professor.[ref]
Ihlen is first author of the 1984 primary study comparing cardiac output determined by Doppler echocardiography with independently obtained values. Ten patients were studied using thermodilution at rest and during dobutamine infusion, and eleven using the Fick method at rest. This design tested an imaging-and-flow measurement against different physical reference methods and across changing flow conditions.[ref]
The measurement combines complementary quantities. The velocity-time integral supplies a length-like integral over a beat, while a measured anatomical area converts a representative integral into stroke volume. Multiplication by heart rate then gives cardiac output. An image alone, a peak velocity alone and an integrated velocity with an appropriate area are different kinds of evidence.
An original sensitivity example shows why the geometry matters. If an area is computed as , a diameter overestimate by multiplies the estimated area and, at unchanged velocity integral, the estimated volume by . Thus a modest diameter error produces a volume error even when the Doppler integral is reproduced perfectly. Comparison studies assess the complete measurement chain rather than only the repeatability of one display.
Figure 1.
Halfdan Ihlen in the portrait accompanying his colleagues' memorial
. The external portrait appears immediately before the opening biographical paragraph in the Norwegian Medical Association journal memorial.
Miguel A. Quiñones 2026-11-05
Miguel A. Quiñones is a cardiologist credited as chair and first author of the American Society of Echocardiography's 2002 recommendations on quantifying Doppler echocardiography. The primary report's byline gives his name and role, while its technical sections explain how acquisition methods determine the interpretation of recorded velocities.[ref]
The report distinguishes pulsed-wave Doppler echocardiography, which selects a sampling region but has pulse-rate aliasing limits, from continuous-wave Doppler echocardiography, which records high velocities without unique depth localization. This distinction is central when turning a spectral envelope into a physiological estimate: the measured signal must correspond to the anatomical quantity used in the model.[ref]
An original sensitivity example illustrates another issue emphasized by the report. Under the simplified pressure-difference model , a velocity underestimate by changes the calculated result by
The derived pressure difference is underestimated by , even before other model errors are considered. For a stipulated estimate of at the true velocity, the underestimated velocity gives . These numbers illustrate the quadratic mapping rather than provide a clinical threshold or a patient result.
The report explicitly notes this amplification when discussing beam orientation and pressure estimates.[ref] The contribution documented here is a practical, quantitative measurement framework. Reproducibly tracing a waveform and establishing the accuracy of a derived physiological value remain different tasks.