Cardiac output is the volume of blood pumped by one ventricle per unit time. With stroke volume and heart rate , . The product connects beat-by-beat mechanics to total flow.
For an invented arithmetic example, beats per minute and millilitres per beat give millilitres per minute, or litres per minute. A change in heart rate alone need not produce the proportional output change if filling and stroke volume also change.
Cardiac index is cardiac output divided by body surface area:When is in L/min and area in m, its units are L/(min m). Despite the word index, it is not dimensionless. A primary comparison of thermodilution and estimated Fick principle measurements explicitly indexed output to body surface area for its analyses.[ref]
An original comparison shows how normalization can change ranking. Output 5 L/min with area 2 m gives 2.5 L/(min m). Output 4 L/min with area 1.5 m gives about 2.67 L/(min m). The second output is lower in absolute terms but higher after this area normalization. Neither statement contradicts the other.
The denominator is often estimated rather than directly measured. If the Mosteller formula is chosen, with numerical height in centimetres and body mass in kilograms, thenThe unit-specific area equation is documented in the official VA technical manual.[ref]
Formulas for Body Surface Area Calculator in the VA Clinical Reminders Manager's Manual. Printed p.36
Choosing an area model is consequently part of defining the reported index.For small input errors, . An overestimated area can lower the index without changing the underlying output measurement. Area normalization also does not by itself account for every difference in metabolism or body composition. The quantity is a standardized way of expressing flow relative to one body-size measure, not an additional independent observation of how much blood the heart pumps.
Pressure-flow distinction in cardiovascular assessment is the separation of blood pressure, a mechanical loading quantity, from blood flow, a volume transported per unit time. Cardiac output is a flow rate. A pressure reading alone does not specify the volume of blood delivered by the heart.
In a simplified steady model,where is the pressure difference across the represented vascular region, is its blood flow and its effective vascular resistance. The difference between upstream and downstream blood pressure matters, rather than one pressure considered in isolation. The pressure-gradient and resistance account is developed in the primary physiology text.[ref]
Anatomy and Physiology 2e by J. Gordon Betts and others. §20.2, Blood Flow, Blood Pressure, and Resistance
An original counterexample holds the pressure difference fixed at 90 mmHg. With mmHg/(L/min), flow is 5 L/min; with mmHg/(L/min), flow is 3 L/min. The same driving pressure can accompany different delivery rates. Conversely, at fixed flow a higher measured pressure difference can represent a higher effective resistance.
The quantities also have different dimensions. The product has units of energy per time, describing a hydraulic rate of mechanical energy transfer in this model. A pressure alone has neither flow units nor power units.
A primary coronary thermodilution apparatus combined a pressure/temperature-sensing guidewire with a controlled infusion catheter; its flow estimate used infusion rate and temperature measurements.[ref]
Direct volumetric blood flow measurement in coronary arteries by thermodilution by Wilbert Aarnoudse and others. Abstract, Methods
The availability of pressure and thermal signals in one instrument does not make them the same observable. Finally, pulsatile circulation includes storage and changing vessel geometry, so the steady resistance relation is an explanatory approximation. Matching time averages, anatomical sites and model assumptions is part of interpreting pressure and flow together.The Fick principle infers blood flow from the rate at which a transported substance is added to or removed from blood and the corresponding concentration difference. For whole-body oxygen consumption in a steady state, conservation of mass giveswhere is cardiac output, is arterial oxygen content and is mixed venous oxygen content. The arteriovenous oxygen content difference must match the tissue bed whose oxygen consumption is measured. The equation follows by subtracting outgoing oxygen transport from incoming transport ; it assumes no continuing accumulation of oxygen within that system.
For a constructed example, oxygen consumption of mL/min and an arteriovenous oxygen content difference of mL/dL imply dL/min, or L/min. Keeping the decilitre in the denominator prevents a factor-of-ten unit error. Using only a difference of oxygen saturation would omit the hemoglobin concentration needed to obtain oxygen content.
Direct implementation measures oxygen consumption, together with arterial and appropriately mixed venous blood samples. An estimated implementation substitutes a model for oxygen consumption. These are different measurement procedures even though they use the same balance equation. A 2017 comparison explicitly studied thermodilution against estimated-oxygen-uptake output, rather than treating estimated uptake as an exact measured input.[ref]
At fixed measured content difference, a error in assumed oxygen consumption produces a error in inferred cardiac output. More generally, differentiating the Fick principle gives . Thus a small content difference magnifies a fixed absolute sampling error.
Oxygen-uptake assumptions in estimated Fick output arise when a Fick principle calculation substitutes predicted oxygen consumption for a direct measurement. With an arteriovenous oxygen content difference ,The measured blood samples and the predicted numerator are different sources of information. Precise arterial oxygen content and mixed venous oxygen content measurements cannot by themselves validate the assumed oxygen consumption.
A primary comparison explicitly examined estimated-oxygen-uptake Fick principle output against thermodilution. Its clinical observations therefore compare particular measurement procedures, not a conservation identity against an unrelated physical law.[ref]
An original exact error decomposition isSuppose actual oxygen consumption is mL/min and mL/dL. Actual cardiac output is then dL/min, or L/min. Assuming mL/min with the correct content difference produces L/min. If the measured content difference were also underestimated to mL/dL, the two errors would cancel numerically and again produce L/min. Agreement of the final answer would not prove either input accurate.
The numerator must also represent the state during sampling. A prediction for one physiological condition need not describe oxygen consumption after a change in activity or metabolism. The steady-state balance assumes compatible sampling and no continuing oxygen accumulation within the represented system. Near a small content difference, even a modest absolute error in can strongly change the inferred blood flow. Reporting estimated uptake as an assumed input keeps these model and sampling limitations visible.