Common attenuation in third-order pulse correlation multiplies the entire input intensity profile by one constant factor before the correlation is formed. For the ideal signal
replacing by gives . All unnormalized lobes scale together, so division by the central peak removes this common factor. The primary correlator paper defines the three-intensity-factor integral and implements it through second-harmonic generation and sum-frequency generation.[ref]
The factor is an intensity transmission. An optical field-amplitude factor instead gives intensity factor and correlation factor . Confusing these conventions changes the predicted power law. A spectral filter that reshapes or chirps the pulse is also not necessarily a common scalar attenuation.
An original example takes an ideal central signal 100 and a side lobe 1 in consistent detector-signal units. Halving the full input intensity gives central 12.5 and side 0.125; their ratio remains 0.01. In contrast, attenuation scaling of a third-order correlation ghost changes only the delayed replica and predicts different real-lobe and ghost powers. A common attenuator cannot perform that selective test.
A fixed background changes what normalization appears to show. Add one unremoved signal unit to both locations. Before attenuation the observed side/center ratio is . After common intensity transmission , it is . The apparent side feature has grown relative to the peak even though the optical profile did not change. Detector baseline subtraction and a verified linear readout are therefore part of the experiment.
Shot-to-shot intensity variation supplies another consequence. Let the common intensity multiplier be , where has zero mean. Then
For equally likely multipliers 0.9 and 1.1, the mean intensity is unchanged but the mean cubic signal is times the unit-intensity signal. This cubic intensity-noise bias in pulse correlation shows why cubing a mean input is not equivalent to averaging third-order signals. The calculation assumes the pulse shape is unchanged on each shot.
A controlled check records pulse intensity alongside the correlator signal, varies a broadband common attenuator, and tests cubic scaling in an unsaturated interval after background correction. Failure of that test can indicate detector nonlinearity, pulse reshaping or an uncontrolled background; it does not uniquely identify a particular fault. The ideal law applies only while the nonlinear gate and optical overlap retain their stipulated response.
Third-order correlation brightness weighting is the way bright shots contribute disproportionately to an averaged nonlinear correlation trace. A normalized average trace is a weighted mean of shot-normalized shapes, with weights set by their central correlation signals rather than by how often the shots occur.
Let a nonnegative, background-corrected third-order trace on shot be . Define its central signal and normalized shape . Then the experimentally distinct averages are
and the equal-shot mean . The nonnegative sum to one, but are equal only when the are equal. Here “central” denotes the specified zero-delay signal, not whichever noisy sample happens to be the largest.
For identical pulse shapes multiplied by intensity factors , the ideal integral scales as . The primary correlator implements this three-intensity-factor gate using second-harmonic generation followed by sum-frequency generation.[ref] If shapes change, can depend on duration and overlap as well as brightness, so pulse energy alone need not determine the weight.
An original two-class example has equally frequent classes with and at one chosen delay. Their equal-shot mean ratio is , but the normalized summed trace gives
The bright class supplies eight ninths of the central signal despite representing only half the shots. Neither result is an arithmetic mistake: they estimate different summaries of the stipulated ensemble.
For an ensemble with finite moments and , the distinction can be expressed exactly through covariance:
Unchanged normalized shape makes the covariance zero, even with large brightness fluctuations. Shape–brightness dependence can make it nonzero; cubic intensity-noise bias in pulse correlation alone does not prove a contrast change.
A shot-resolved pulse-contrast estimator needs synchronized intensity information and a stated selection rule. Thresholding weak shots or dividing by a noisy central signal can introduce further selection and ratio errors. Report whether normalization occurred before or after averaging, retain detector baseline subtraction, and test readout linearity. A smooth averaged trace is not a representative single shot unless those assumptions are justified.