Combining the lubrication gravity-current flux with vertical imbibition under a draining liquid layer givesThe injected volume is the integral of , not just the surface current thickness. The model neglects horizontal subsurface flow and applies only where the substrate is wetted and the surface current supplies its drainage.
For a one-sided draining gravity current with injected volume per unit width , defineThe similarity solution satisfieswhere . The inlet condition is , the integral of is one, and both depths vanish at the advancing front. The endpoint gives and depends on and .