Acquisition-time sensitivity to tail-model parameters measures how an inferred recording extension changes when the assumed optical tail changes. In the positive-duration branch of acquisition duration from an exponential tail-energy tolerance, writeHere bounds the initial tail power, is its decay time and the tolerated missed energy. Their first-order relative effects areThese logarithmic condition numbers of a tail-acquisition requirement distinguish a fractional amplitude error from a fractional decay-time error. For a stringent tolerance with large , decay-time sensitivity stays near unity while amplitude sensitivity decreases.
For an original example, take , and . Then and . Let the independent standard uncertainties of and be and , with the tolerance fixed. The amplitude contribution to is ; the decay-time contribution is . Adding their variances gives , about .
Correlated fitted parameters require covariance terms in this propagation.[ref]
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results by Barry N. Taylor and Chris E. Kuyatt. Appendix A, equation A-3
A standard uncertainty is not a guaranteed recording margin: a worst-case requirement needs a justified allowed parameter set, as in the parent article. The zero-duration boundary is also outside this smooth positive-branch calculation.Physically, these parameters must describe the unrecorded optical power, not merely an electrical detector tail. NIST separately measured the detector/cable/oscilloscope response before correcting pulse measurements.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. Appendix C.1–C.2, printed pp. 36–37
A precise fit to the wrong response component does not justify the optical envelope or its acquisition-time bound.Logarithmic tail-duration change at the zero-extension boundary describes a recording requirement whose input ratio crosses the point where no further acquisition is needed. For fixed decay time , put and . The physical extension isHere the logarithm applies to the input ratio, not to a zero output duration. Logarithmic condition numbers of a tail-acquisition requirement applies only where .
At , the left derivative is zero and the right derivative is . The directional derivative of a clipped logarithmic acquisition time along a signed input change isThus no single ordinary derivative describes threshold-crossing perturbations. Nevertheless, the duration is stable in absolute units:This follows because the positive-part map has Lipschitz continuity with constant one.
For an original interval example, take and a justified input-ratio range . The corresponding duration range is . Its lower part is clipped at zero. Linearizing only on the zero-duration side would incorrectly predict no possible extension even though the allowed set crosses the threshold. A relative error divided by a nominal is undefined, while this absolute bound remains meaningful.
If is uncertain too, optimize the full expression over the justified joint parameter set rather than treating this fixed- inequality as a complete uncertainty analysis. The tail model must bound optical power throughout the missed interval. NIST's calibration apparatus measured detector/cable/oscilloscope response separately, illustrating why a recorded electrical decay cannot automatically certify such an optical envelope.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. Appendix C.1–C.2, printed pp. 36–37
The clipping analysis is an original property of the stated conditional acquisition model.