Minimum incremental motion is the smallest displacement increment that a positioning system can execute repeatedly for the specified input and test conditions. It is an operational motion property, whereas design resolution is derived from the drive geometry and electronic increments. Friction, stiction, elasticity and backlash can make them differ.[ref]
Precision Motion and Positioning: Difference between Micropositioning and Nanopositioning by Physik Instrumente. Glossary, Design Resolution and Minimum Incremental Motion
For an original illustrative test, independently measure the displacement produced by repeated commands from equivalent starting conditions. A nominal 10 nm command gives moves . Their mean is 10 nm, but that mean does not show repeatable 10 nm increments. A nominal 40 nm command instead gives .
Define an example acceptance rule before testing: every measured move must lie within 5 nm of the command, and the readout must have sufficiently smaller uncertainty, stipulated here as 1 nm standard uncertainty. The 10 nm trials fail this rule; the 40 nm trials pass. Among these two candidate increments, 40 nm is the smallest accepted one. It is not a proof of the globally smallest achievable increment because intermediate candidates and other conditions were not tested.
Report the command convention, load, motion direction, starting procedure, displacement sensor, measurement uncertainty and acceptance rule. A rotary encoder on the motor does not automatically measure the final load motion. Independent readout, for example with an interferometer, tests the assembled stage rather than only the commanded count. Positioning repeatability at a target and the ability to make a small move are related but distinct properties.
Articles by others on the same topic