Measurement uncertainty describes the spread of values reasonably attributable to a specified measurand, using the available information. It differs from measurement error, which is a difference from a reference value: the uncertainty can be quantified even when that difference is unknown. A useful result therefore states what was measured, the unit of measurement, the value, and how its uncertainty was evaluated.[ref]
For a wire's electrical resistance obtained from , uncertainty in the voltage and electric current propagates through that measurement model. Shared measurement calibration effects can make the inputs correlated, so adding percentages or treating every contribution as independent can be wrong. The measurement uncertainty budget records those assumptions. Report a standard uncertainty when a standard-deviation scale is intended, or an expanded uncertainty with its stated coverage factor; a bare plus-or-minus number does not specify which was used.
A covariance matrix describes second moments, but does not specify a complete probability distribution. A bounded model can realize a prescribed covariance matrix exactly while keeping every possible error finite. This is useful for checking a nonlinear measurement model without accidentally generating physically impossible inputs; it is a constructed model, not evidence that an actual instrument has that distribution.
For two errors with desired standard deviations and correlation coefficient , let be independent random variables with the Rademacher distribution: each takes and with probability . Set
Both expected values vanish. Since and , direct expansion gives
There are at most four distinct states, each obtained from an equally likely sign pair. Also and . At the second sign has no effect, leaving only two distinct states. If either standard deviation is zero, the corresponding error is zero and its correlation coefficient is undefined; the covariance construction still makes sense.
More generally, a finite-support realization of a covariance matrix exists for every real symmetric positive semidefinite matrix . By the spectral theorem, write using its positive eigenvalues and corresponding orthonormal eigenvectors, and put . Let have independent Rademacher distribution coordinates. The random vector then satisfies
The identity matrix appears because the signs have unit variance and zero pairwise covariance. There are at most distinct states, with component bounds by the Cauchy-Schwarz inequality. When , take . Thus singular covariance matrices are allowed; a nonsingular Cholesky decomposition is not required.
This full sign model also makes robust linear constraints for bounded covariance models exact. To require for every sign state, choose each sign to minimize its contribution. The result is the necessary and sufficient condition
where is the L1 norm. This is a small robust optimization calculation. A physical domain must be checked in the chosen units; clipping inadmissible samples afterwards generally changes both the probability distribution and its covariance matrix.
For example, in correlated threshold and amplitude errors in RC timing, take nominal amplitude , threshold , , and . Use and . Every state has , while the minimum amplitude-minus-threshold is
All four states therefore remain within the RC threshold-crossing time domain. Enumerating them supplies an exact check for this particular bounded error model; it does not establish the instrument's actual tail probabilities.
The nonuniqueness of bounded uncertainty laws with a fixed covariance is visible even in two dimensions. Let
For independent fair signs , both and have covariance matrix because is an orthogonal matrix. Yet the first coordinate of is always , whereas that of is with probability and each of with probability . Hence is respectively zero and one half, despite identical expected values and covariance matrices. A nonlinear risk calculation needs more than those moments.
Figure 1.
Two bounded four-state error models with identical covariance and different tail probabilities. All points are constructed, not measured data.
Details.
Nonuniqueness of bounded uncertainty laws with a fixed covariance means that specifying finite bounds, expected values and a covariance matrix can still leave several different joint probability distributions. They agree on the variance of every linear combination of the errors, but can disagree on threshold probabilities and nonlinear outputs. A particular construction in bounded errors with prescribed correlation therefore requires a distributional assumption beyond its second moments.
Here is an original example with a common allowed box . In model A, and are independent fair signs: the four points each have probability . In model B, the four points each have probability . Both are bounded, have zero expected value, and satisfy
For model B, each squared coordinate is two at two of the four points and zero otherwise, proving its unit variance directly. Its zero covariance does not make the coordinates independent random variables: when is nonzero, must vanish. The common box is an allowed deterministic bound; its boundary need not be attained by every model.
The linear output has expected value zero and variance two under either model. Yet under model A it takes with probabilities , while model B gives only with equal probabilities. Consequently,
Even a linear output's threshold risk is not fixed by its variance. For the nonlinear output , model A gives always and model B gives always. Thus the complete output law, and even a nonlinear output's expected value, can differ.
The law of propagation of uncertainty computes first-order output variance from sensitivity coefficients and input covariance; it does not identify all probabilities. NIST correspondingly requires distributional justification to assign a confidence level to an uncertainty interval.[ref] The finite counterexample above is an original exact calculation. For guaranteed linear limits, robust linear constraints for bounded covariance models must use the chosen support of a probability distribution, rather than treating a covariance matrix as a support description.
Robust linear constraints for bounded covariance models require a linear inequality to hold for every error state admitted by the selected bounded model. A covariance matrix fixes second moments; the robust guarantee additionally depends on the support of a probability distribution or other specified uncertainty set. This distinction matters when a physical limit must never be crossed within the model.
Let as in finite-support realization of a covariance matrix, where all coordinates of are independent fair signs. Then . For nominal input , require for every sign state. Writing , direct minimization gives
Each sign can independently oppose its coefficient, including when some coefficients vanish. Thus the exact necessary and sufficient condition is , using the L1 norm. The same extremum holds over the full box because a linear function attains an extreme at a vertex. This is a support function calculation in robust optimization; the general worst-case formulation and its dependence on the uncertainty set are illustrated in the primary optimization text.[ref]
For an original two-input example in volts, let and , with independent fair signs . The covariance matrix is . To keep the actual first input at least as large as the second, let the nominal difference be . Then
A nominal difference of fails in the state , despite being positive nominally. A difference of leaves a guaranteed margin under this model. Using only the separate bounds , would demand , because that larger box admits joint states the sign model forbids.
The standard deviation of is instead . It is not the hard bound . A different bounded law with the same covariance matrix can change the hard bound, as nonuniqueness of bounded uncertainty laws with a fixed covariance explains. For several linear inequalities, apply the support calculation to each row. This verifies an assumed model's feasible states; it does not establish that the chosen support contains every error of an actual instrument.
A sensitivity coefficient describes how an estimated output of a measurement model changes when one input changes slightly. For , the first-order coefficients, evaluated at the input estimates, are
A sensitivity coefficient can have a sign and a unit of measurement: for an output in ohms and an input in volts, its unit is ohms per volt. The GUM also describes estimating sensitivity coefficients experimentally by varying inputs.[ref]
In a measurement uncertainty budget, propagation of uncertainty uses these coefficients to transform input variances and covariances:
Here denotes an input standard uncertainty. The derivative's sign disappears from its independent variance term but still matters in a covariance term.[ref]
For an original electrical resistance example, , and give and
Independent input standard uncertainties of0.1volt and0.02ampere each contribute0.05ohm on the output scale, giving . A larger sensitivity coefficient alone does not identify the dominant uncertainty: the input standard uncertainty and any correlations also matter.
The derivative is a local approximation. If the input spread spans a strongly nonlinear part of the measurement model, first-order propagation of uncertainty can be inadequate even when every derivative has been computed correctly.
An expanded uncertainty is , where is the combined standard uncertainty and a stated coverage factor. A result written aims to describe an interval with a specified coverage interpretation.
If a normal approximation is appropriate and the standard uncertainty is well determined, gives approximately 95 percent coverage. This interpretation requires those assumptions; multiplying by two alone does not prove a coverage probability. Report the factor and the basis for its choice.[ref]
A coverage factor multiplies combined standard uncertainty to give expanded uncertainty, . It is dimensionless. Choosing it requires a target coverage and assumptions about the result's distribution and the reliability of the estimated standard deviation.
For a normal distribution with known standard deviation, gives a central interval of about 95 percent probability. With a small sample and an estimated variance, an appropriate Student's t-distribution quantile can be larger. A stated factor therefore communicates a method, not merely an error-bar width.[ref]
A Type B evaluation of uncertainty uses information other than a statistical analysis of repeated observations of the current quantity. Examples include calibration certificates, manufacturer specifications and knowledge of resolution. It describes the evaluation method, not whether an effect is systematic or random.
If a rounding error is reasonably modeled as uniform on , its standard uncertainty is . The distribution assumption is part of the evaluation and should be justified by the available information.[ref]
A Type A evaluation of uncertainty obtains an uncertainty component through statistical analysis of observations. For independent repeated readings with sample standard deviation , the estimated standard uncertainty of their mean is .
Independence and stability matter: serially correlated readings do not generally provide independent pieces of information. Type A and Type B evaluation of uncertainty classify how components are assessed, rather than separating random measurement errors from systematic error.[ref]
A record of uncertainty contributions in a specified measurement model, their evaluation methods, sensitivity coefficients and relevant correlations. For , first-order propagation of uncertainty gives . A correction for a known systematic error can itself have uncertainty; applying the correction does not remove that contribution.[ref]
A standard uncertainty expresses a component of measurement uncertainty as an estimated standard deviation. It has the same unit of measurement as the measurand: describes a spread in a length, rather than a percentage or a known measurement error. A Type A evaluation of uncertainty uses statistical analysis of observations; a Type B evaluation of uncertainty uses other information, such as a reference certificate or instrument specification. These classify the evaluation method, not whether a physical effect is random or systematic.[ref]
For independent repeated readings with common variance, the sample mean has estimated standard uncertainty , where is their sample standard deviation. This is the standard error of the mean; the scatter instead describes individual readings. Repetition reduces this contribution, but a shared measurement calibration contribution remains. A quoted tolerance supplies a different example: assigning a continuous uniform distribution within those bounds gives . That assignment is a model of the available information, not a consequence of repeating measurements.[ref]