A minimum-variance spectral contrast orthogonal to a reference shape estimates a desired signal amplitude while exactly rejecting one fixed nuisance shape. Let , with known shapes and a positive-definite noise covariance matrix . Choose to minimize , subject toThe constraints retain unit signal response and reject the reference amplitude, as in projection of shared-scale uncertainty onto a spectral contrast. The quadratic variance includes the full noise covariance.[ref]
Remove the reference component in the inverse-covariance geometry:For nonzero and , the minimizing contrast and its variance areFor a short proof, every other feasible contrast is with . Since is a linear combination of those shapes, the cross term vanishes, leaving the added nonnegative variance . This is a constrained best linear unbiased estimator.
In an original three-channel example, take , and . The optimum is , with variance . Equal subtraction of the two reference channels, , has variance . The quieter third channel receives more of the subtraction.
If the desired and reference shapes are proportional, and no unit-response rejecting contrast exists. The noise penalty from nearly parallel signal and reference shapes already becomes large as approaches zero. This construction assumes fixed known shapes and covariance; estimating them from the same noisy spectra requires additional uncertainty terms.
The noise-whitened angle between spectral signal and nuisance shapes measures their separation in units of measurement noise rather than raw plotting units. For nonzero shapes and a positive-definite covariance , choose a square whitening transformation with . The angle isIt is the ordinary Euclidean angle after whitening. Both parallel and antiparallel shapes are indistinguishable up to an unknown nuisance amplitude; the precision penalty depends on , as in noise penalty from nearly parallel signal and reference shapes.
For an original example, take raw shapes , and . The plotted shapes are orthogonal, but whitening gives and . Thus and . The second channel, which separates their signs, is noisy. Rejecting the nuisance multiplies the optimum variance by , or standard uncertainty by .
The invariance of noise-whitened spectral angles to the whitening factor follows from . Different valid square whitening factors can rotate the whitened coordinates without changing the angle. Likewise an invertible change of measurement units transforms both shapes and covariance, leaving the inverse-covariance expression unchanged. Rescaling only the displayed curves while leaving their noise model fixed is a different operation.
The covariance must describe the actual measured channels and shared errors, using the full propagation rule.[ref]
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results by Barry N. Taylor and Chris E. Kuyatt. Appendix A, equation A-3
If is singular, first restrict to its physically allowed range; an unrestricted inverse whitening factor does not exist.The primary stimulated-Raman experiment described systematic spectral noise and subtraction of a pure-solvent reference.[ref]
Femtosecond Broadband Stimulated Raman: A New Approach for High-Performance Vibrational Spectroscopy by David W. McCamant and others. Results and Discussion, observed noise versus shot-noise limit and pure-solvent subtraction
The angle above assesses which desired patterns remain distinguishable after such nuisance rejection under a stated covariance. It does not establish that an estimated reference shape or noise model is itself accurate.