Use the kinematic fluxes , and . In the steady Boussinesq approximation, the non-Boussinesq top-hat plume equations reduce toEliminating gives , where the integration constant vanishes for a pure plume from a point source. Write and . The two balances give and . The Boussinesq point-source plume is thereforeHere and tend to zero at the source, while remains positive. The plume Froude number is independent of height:The ideal point source is a far-field similarity idealization. Since , the Boussinesq approximation fails near and is valid only when . In terms of , this requires ; the density formula must not be extrapolated into its unphysical negative-density region.