A system is causal if outputs up to time depend only on inputs up to time . For a time-invariant convolution system this is equivalent to an impulse response that vanishes for .
It is BIBO stable if every bounded input produces a bounded output. For a causal convolution system, absolute integrability
is the standard stability criterion.
Taking Laplace transforms and using gives
Hence the transfer function is
Its pole is at , and its causal impulse response is
It is absolutely integrable exactly when
For ,
Its only pole is , so direct inspection gives stability exactly when
apart from the excluded boundary.
For the Nyquist stability criterion, let . The open loop has no right-half-plane poles, so . On the clockwise right-half-plane contour, the winding number of about zero, equivalently of about , satisfies
where is the number of unstable closed-loop poles. The Nyquist locus
is the circle with diameter joining and on the real axis, completed by its conjugate half.
If , this circle does not wind around , so , , and the loop is stable. If , it winds once with , so , and the loop is unstable. Nyquist therefore gives precisely the same condition .

Articles by others on the same topic (0)

There are currently no matching articles.