Exposure-time allocation for a Raman gain ratio must respect channels that are recorded together. The ideal photon-budget allocation for a Raman gain ratio permits four independently adjustable exposures. A probe/reference detector pair instead has a common pump-on exposure and a common pump-off exposure .
Let the four positive photoelectron rates be during pump-on and during pump-off. Form the gain ratio from exposure-normalized rates. For independent large counts limited by shot noise, its approximate relative variance is
With a fixed live-time budget , differentiation or the Cauchy-Schwarz inequality gives
For an original example, let both pump-on rates be and both pump-off rates be . Then , . A one-second live-time budget is best split into second on and second off. Its predicted relative standard deviation is , compared with for equal times.
The 2003 primary stimulated-Raman apparatus recorded probe and reference spectra together, using 97 ms exposures followed by 10 ms readout with the detector-exposure shutter closed. The Raman-pump shutter changed state during readout.[ref] These acquisition details motivate grouped exposure constraints and readout overhead in Raman exposure allocation. The optimization above uses live time, stationary rates and negligible read noise; a wall-clock budget, detector saturation or sample drift can change which exposures are feasible.
The shot-noise precision of a Raman gain ratio is the statistical precision expected from finite detected photoelectron numbers under a stated counting model. Write the Raman pump-on pump-off gain ratio as , where are pump-on probe/reference counts and pump-off probe/reference counts. For large independent Poisson counts, applying first-order propagation to gives
The parent article derives the equal-count limit. Independence, large counts and a calibrated conversion from readout units to photoelectrons are assumptions, not consequences of taking a ratio.
An original imbalanced example has and . The relative standard uncertainty is about . Increasing the three bright channels tenfold only reduces it to about : the weakest count channel dominates. Multiplicative detector-gain corrections can make the mean ratio appropriate to the optical experiment, but they do not create additional photoelectrons.
A simple photon-budget allocation for a Raman gain ratio makes the trade-off explicit. If the four mean counts sum to , the Cauchy-Schwarz inequality gives
Equality in this ideal unconstrained budget requires equal counts. Near unity gain, four approximately equal means totalling give about relative precision. Actual optical ratios, reference splitting and exposure constraints may prevent exact equality.
The primary FSRS experiment explicitly compared its computed photoelectron shot-noise limit with observed baseline noise and found additional detector structure; it averaged repeated gain spectra and discussed pixel-dependent corrections.[ref] A counting limit is therefore a useful benchmark, not a guarantee of achieved experimental sensitivity.