The ratio of the heat flux needed to reach departure from nucleate boiling to the actual local heat flux. Greater values indicate more margin under the model and correlation used.[ref]
The fuel-temperature derivative of reactor reactivity associated with thermal broadening of nuclear resonances, with the other state variables specified. In ordinary uranium-fueled water reactors it is negative: heating the fuel increases effective resonance capture. Its magnitude depends on spectrum, fuel state and resonance self-shielding, so its sign does not determine how its magnitude changes under a lattice redesign.[ref]
Use a common comparison for all of question2: retain the same number and height of fuel rods and approximately the same normalized rod-power shape; reduce fuel lattice pitch by making the active core cross-section smaller. Compare otherwise similar operating states of an initially under-moderated reactor, typical of a pressurized water reactor. Rod number, core height, reflector and control settings are not all fixed explicitly by the question, so these are stated assumptions. Keeping the external core envelope fixed while inserting more rods would be a different comparison.
Reactor reactivity normally decreases at unchanged controls and reference temperatures. Less water per fuel atom reduces neutron moderation and increases resonance absorption during slowing down. Reduced absorption in the water partly compensates, but on the under-moderated side the net lattice tendency is lower multiplication. This is the usual under-moderation argument, rather than a universal rule for arbitrary fuel lattices.[ref]
Neutron leakage would usually tend to increase. The smaller transverse core extent increases the geometric tendency to leak, and reduced moderation generally increases the slowing-down distance. There are competing changes in fuel absorption, transport lengths and reflection. Thus a definite leakage fraction needs the actual core and reflector arrangement; the usual increase is a qualitative tendency, not a geometric theorem for every redesign.
The Doppler coefficient of reactivity remains negative under the ordinary uranium-fuel assumptions. Increasing fuel temperature broadens absorption resonances, increasing effective uranium-238 resonance capture and reducing reactor reactivity. This stabilizing fuel-temperature effect is distinct from moderator-density feedback.[ref] Greater importance of resonance absorption can make this feedback more important in a tighter lattice, but its change in magnitude is not fixed by pitch alone: spectrum, resonance self-shielding, fuel composition, burnup and the reference fuel temperature all enter the derivative.
The fraction of fissions in uranium-238 tends to increase. The harder neutron spectrum gives more opportunity for fast fission before neutrons slow below the uranium-238 fission threshold. This concerns the fraction of the total nuclear fission rate, not an assertion that the total thermal power increases; that power is held fixed.
Continue the same-rod-number and same-height comparison from part(a), and assume unchanged pump speed, similar inlet conditions and single-phase forced flow for the normal-operation hydraulic argument.
Core power density increases. The active core volume decreases while total thermal power stays fixed. The fuel's own average volumetric power and the mean fuel linear heat rate do not increase merely from bringing the same rods closer together: fuel volume and rod count are unchanged.
Coolant mass flow rate normally decreases. Tighter passages reduce flow area and hydraulic diameter, increasing the core's hydraulic resistance. The unchanged centrifugal pumps do not enforce constant flow. The pump operating point moves to the intersection of the same pump curve with the steeper system-resistance curve, normally giving smaller flow at greater pump head.[ref]
The core pressure drop normally increases for the usual pump curve. Its resistance at any given flow is higher. At the new, smaller flow, unchanged external piping and component losses are smaller, whereas a conventional falling pump head-versus-flow curve gives greater available head. The core takes the difference. This conclusion uses the stated pump-curve assumptions; holding flow fixed or holding pump head fixed would be different models. The exact new flow and pressure drop need both system and pump characteristics.
Fuel temperature would normally tend to rise, especially downstream, if the loss of flow increases coolant heating without a compensating improvement in film heat transfer. At fixed inlet state,
shows that smaller total mass flow rate raises the bulk coolant temperature rise. At unchanged local fuel linear heat rate, the fuel-to-surface conductive contribution is approximately unchanged if material properties and gap conditions are held fixed. Its boundary temperature and the coolant film drop can nevertheless change.
The local coolant mass flux is . Both total flow and flow area decrease, so the sign of the change in , the heat transfer coefficient and the fuel temperature cannot be deduced from total flow alone. Changes in power peaking and inlet conditions add further qualifications to the usual hotter-fuel tendency.
The minimum departure from nucleate boiling ratio would commonly decrease, implying reduced boiling margin, but its sign is conditional. The defining local ratio is
The numerator is the critical heat flux for the local conditions, and the denominator is actual rod-surface heat flux.[ref] The mean surface heat loading remains approximately unchanged for the same rods and total power. Greater coolant enthalpy rise tends to reduce margin, while changes in , geometry, pressure and local power determine the actual critical heat flux. A geometry-appropriate correlation or experiment is needed for a definite MDNBR change; unchanged hardware does not supply it.