Temperature labels thermal equilibrium: two internally equilibrated bodies have the same temperature when contact permitting only heat exchange produces no net heat transfer. The zeroth law of thermodynamics makes the comparison transitive. If bodies A and B separately reach thermal equilibrium with the same thermometer without appreciably disturbing either body, they agree with each other. This is what lets a gas thermometer compare a metal block with water, despite their different internal energies and heat capacities. Insulation alone makes no such comparison: it can prevent heat transfer between bodies at different temperatures. [ref]
1.1 Temperature and Thermal Equilibrium. Ling, Moebs and Sanny, University Physics Volume 2, section 1.1: temperature and the zeroth law
The zeroth law of thermodynamics establishes equality comparisons, but does not choose a numerical scale. Thermodynamic temperature supplies an absolute scale consistent with Carnot's theorem and entropy. For a simple compressible system at thermodynamic equilibrium with fixed particle number and composition,Here is internal energy, is entropy, and is volume; the second equality assumes the derivative can be inverted. Temperature is a thermodynamic conjugate variable to entropy and belongs to the intensive and extensive thermodynamic quantities as an intensive quantity. Its partial derivative tells us how much internal energy must change per unit change of entropy under the stated constraints. More general systems require their other mechanical and material variables to be held fixed too. [ref]
For an infinitesimal quantity of heat transferred from A to B, with no work or matter exchange, the equilibrium entropy changes giveFor ordinary positive temperatures, spontaneous heat transfer from increases total entropy; thermal equilibrium has . This comparison uses changes in entropy, rather than the total internal energy contained in either body. A small hot object can have less internal energy than a large cool one. See entropy maximization under thermal contact for the equilibrium criterion and negative temperature for the special case of bounded energy spectra.
Express absolute thermodynamic temperature in kelvin, and a Celsius reading in degree Celsius:The offset is exact: corresponds to , and to . Their absolute temperature ratio is ; dividing their Celsius readings gives a different number. Thus gas thermometer pressure ratios and Carnot's theorem require thermodynamic temperature. The modern SI definition of the kelvin fixes the Boltzmann constant ; a reference bath realizes or transfers the scale rather than defining that constant.[ref]
The International System of Units (SI), ninth edition, SI Brochure. section 2.3.1: kelvin and Celsius temperature
Temperature is not universally the mean kinetic energy of a particle. In a classical, nonrelativistic ideal gas at thermal equilibrium, the equipartition theorem gives the mean translational kinetic energy relative to the gas's bulk motion:Here is particle mass, its velocity, and the mean flow velocity. In this regime, different particle masses at the same temperature have equal mean translational kinetic energies but different characteristic speeds. A moving gas can also carry bulk kinetic energy without being hotter in its rest frame. Internal molecular modes and quantum statistics require further care; the equipartition theorem has classical assumptions, whereas the equilibrium entropy definition applies more widely. [ref]
https://davidtong.org/teaching/statistical-physics/statmechhtml/S2#S2.SS2.SSS1. Tong, Statistical Physics, section 2.2.1: classical equipartition and its limits
An average of a specified temperature record over a stated interval or ensemble. For a time mean, observations must represent elapsed durations: irregularly spaced readings generally require time weighting. The half-sum of a daily maximum and minimum is a conventional daily statistic and need not equal the continuous time mean.
An instrument for estimating high temperatures. The physical response and calibration must be specified; thermal expansion, a calorimetric transfer, electrical properties and emitted radiation lead to different methods and different limitations.
The temperature within soil or rock beneath the ground surface. Its time dependence can be governed by thermal conduction, fluid transport and internal heating; a homogeneous conduction-only approximation gives a heat equation.
For an isotropic nonrelativistic Maxwellian particle population, kinetic temperature describes random translational motion, with mean kinetic energy per particle after subtracting bulk motion. Different species can have different kinetic temperatures outside thermal equilibrium. A rotational excitation temperature equals the kinetic temperature only when the excitation is sufficiently thermalized; a radiation brightness temperature is another distinct quantity.
The temperature parameter describing a thermal electron velocity distribution. Electron-impact excitation coefficients depend on it through both the speed distribution and excitation thresholds. In a dilute plasma, electron and ion temperatures need not coincide.
Absolute zero is the zero of thermodynamic temperature, corresponding to . For a system with a nondegenerate ground state, equilibrium entropy approaches zero as temperature approaches absolute zero. This does not mean that every quantum degree of freedom loses its zero-point energy. The entropy statement and the operational unattainability of absolute zero require their respective physical assumptions.
A cooling method that reduces an applied magnetic field while suppressing heat transfer to or from the material. For a suitable material exhibiting paramagnetism, an approximately reversible field reduction can lower its temperature at approximately constant entropy.
The preparation matters as much as the field reduction. First establish thermal equilibrium with a cold heat bath, then raise the magnetic field while maintaining the bath temperature: this is magnetization in an isothermal process. The bath accepts heat and the material loses magnetic entropy. Next open a heat switch, thermally isolating the working material, and lower the magnetic field. If the sweep maintains internal thermal equilibrium with negligible entropy production, this second leg is an isentropic process. An adiabatic process alone does not guarantee constant entropy.
The attraction is a controllable energy scale: changing the magnetic field changes the separation of magnetic energy levels, even across a thermally insulating gap. This lets an already cold solid become colder without needing a colder contacting heat bath. A practical refrigerator also needs a load, a period of absorbing its heat, and a reset that rejects accumulated entropy to the bath. A single field sweep has finite cooling capacity.
Let independent spin- moments and a load with heat capacity remain in equilibrium during reversible isolated demagnetization. Then . Fully removing the field raises each spin entropy by its initial magnetic entropy deficit. Total entropy conservation gives , yielding the title result. The formula assumes positive final temperature, validity of the load law throughout the interval, negligible additional entropy contributions and an attainable equilibrated low-field endpoint. Interactions require an actual many-body entropy instead of the independent-spin expression.
When the entropy of independent magnetic moments dominates, a reversible isolated change fixes . Lowering the field therefore lowers temperature as . Other heat capacities, internal interactions and residual fields limit this ideal relation.
Magnetic entropy counts the uncertainty in the occupied magnetic microstates. For independent localized magnetic moments with one-site probabilities ,where counts sites and is the Boltzmann constant. This is the Gibbs entropy for the magnetic degrees of freedom. Equal occupation of two states gives ; certain occupation of one state gives zero. Calling this disorder is useful only if the relevant states and their probabilities are specified. In an interacting material, correlations generally prevent replacing the many-body Gibbs entropy by this sum of independent one-site contributions.
Increasing the magnetic field at fixed positive temperature favors lower magnetic energy levels, reducing magnetic entropy. During ideal isolated demagnetization, both the level separation and temperature fall together, leaving the occupation probabilities unchanged. Thus the independent-spin idealization cools without increasing spin disorder along the isolated leg. When a real crystal's vibrating lattice also cools, its lost entropy can instead be taken up by the magnetic degrees of freedom. The conserved quantity is the total entropy of the thermally isolated stage, including any attached load in thermal equilibrium.
The magnetic entropy deficit is the entropy increase still available to independent moments as their field polarization is removed. For a spin- multiplet, and the high-temperature deficit is . Isothermal magnetization creates this deficit while rejecting heat to a bath. Subsequent reversible demagnetization can absorb entropy from a cooling load. The deficit, not the initial absolute magnetic entropy, measures that capacity.
For magnetic quantum numbers , energies and , the partition function is . Its entropy is the title expression, a function of alone. At small , . The maximal entropy is at zero splitting. A fixed independent-spin entropy consequently fixes ; an attached heat load changes the combined isentropic path.
Use the independent spin-one-half two-level system with fixed distinguishable sites and Hamiltonian levels , where is the magnitude of the field-axis magnetic moment and is a uniform externally controlled magnetic field. Assume positive temperature, no interactions between sites, and no appreciable lattice or load entropy. The two levels differ by . With inverse temperature , the canonical ensemble gives the one-site and total partition functionsHere the minus subscript denotes the lower energy . Factorization of the partition function requires additive energy and independent sites; there is no particle-exchange factor for these fixed distinguishable sites.
Differentiate the partition function, holding fixed when differentiating with respect to . The internal energy, Helmholtz free energy, total field-axis magnetic moment , and magnetic entropy areThe extensive moment is distinct from magnetization, the moment per unit volume. Direct substitution of into the Gibbs entropy gives the same independently of the free-energy derivative.
At fixed , the magnetic heat capacity isStrict decrease makes invertible on . Constant magnetic entropy therefore fixes , not or separately:The partition function may be used to label these equilibrium states even though the isolated cooling leg has no external heat bath. Actual thermalization of the lattice and load additionally requires a sufficiently fast spin-lattice relaxation; perfectly uncoupled spins by themselves cannot refrigerate an attached object.
The limiting cases are instructive. For , , , and . The moment response reproduces Curie's law. For , and the upper-state occupation is exponentially small. Taking at fixed gives ; taking at fixed gives . The origin has a path-dependent limit. Extrapolating a line of constant to does not construct a usable zero-temperature state or prove that a real material retains independent degenerate spins there.
Choose a fictional two-level refrigerant with , where the upright denotes tesla. This chosen moment is a convenient model parameter, not a fitted property of the historical salt. At bath temperature , raise from to . Then increases from to , soThe last equality assumes a reversible isothermal process of magnetization; negative means the refrigerant rejects heat. The bath gains of entropy, balancing the stage's loss in this reversible limit. An appreciable temperature difference during real heat transfer adds entropy production.
Now open the heat switch and reduce from to . Constant gives . Throughout this ideal cooling leg, , , and . Neither state becomes more probable. Field reduction shrinks the energy gap by ten while preserving the Boltzmann distribution's dimensionless ratio of gap to temperature.
There is a subtle energy check. For the spin Hamiltonian convention used here, external-field interaction energy belongs to , so reversible work done on the spin subsystem is andOn the isolated leg, but increases from to , becoming less negative as the gap shrinks. Integrating at constant supplies exactly . Cooling therefore need not decrease this chosen spin internal energy. An account of work exchanged with a magnet circuit must specify where field interaction energy is assigned before comparing signs. The occupation ratio and temperature prediction do not depend on that bookkeeping choice.
For the isothermal preparation, direct integration gives . The endpoint internal energy difference is , equal to . This independently checks both the rejected heat and the magnetic-work sign in the chosen convention.
William Francis Giauque's 1949 lecture, Some Consequences of Low Temperature Research in Chemical Thermodynamics, credits Peter Debye with an independent proposal. It describes gadolinium sulfate octahydrate in a jacket immersed in liquid helium, with an external solenoid. Exchange gas conducts away heat during magnetization; evacuation isolates the sample before field reduction. A liquid-nitrogen shield reduces radiative heat transfer. Its photograph identifies the 1933 apparatus operated with Duncan Peck MacDougall. An inductance bridge reads the sample's magnetic susceptibility; measuring coils remain outside the evacuated jacket in liquid helium. Increasing magnetic susceptibility indicates cooling, but converting it to temperature using Curie's law becomes approximate as that law fails.[ref]
Some Consequences of Low Temperature Research in Chemical Thermodynamics by William Francis Giauque. Giauque, Nobel lecture, pp. 237–245, Figs. 16–20 and 23–25
The measurement logic deserves a separate check. A changed inductance alone is not an absolute temperature calibration: the sample geometry, applied measuring magnetic field, and constitutive response enter the inference. A modern control would compare the susceptibility-based thermometer with an independently calibrated thermometer over their common range, check recovery after repeated sweeps, and measure subsequent warming to bound incoming heat. These are proposed controls derived from the readout principle, rather than additional procedures attributed to the 1933 experiment. The historical working salt has a richer magnetic level structure than the illustrative two-level paramagnetic cooling model.
Three distinct effects spoil indefinite cooling: extra entropy outside the spin subsystem, additional magnetic energy scales, and irreversible heat or work input. They can be distinguished with a thermodynamic derivative. For a smooth equilibrium Helmholtz free energy obeying , a Maxwell relation givesHere is the total heat capacity participating in the stage's thermal equilibrium. The ideal model has . If its spins share temperature with a field-independent lattice and load of combined heat capacity , thenThe positive slope still means cooling when , but its smaller magnitude gives less cooling per fractional field reduction. For example, a low-temperature Debye model gives a lattice entropy proportional to . As that lattice entropy falls, the spins take up the released entropy; can no longer remain constant. A weak enough coupling to neglect its equilibrium interaction energy can still be strong enough to exchange heat on the sweep timescale.
Interactions between magnetic moments, including exchange interaction and the fields of neighboring magnetic dipole moments, introduce energy scales that do not vanish with the applied . Once they compete with or , the independent-site partition function fails. Correlations and possible magnetic ordering alter the available magnetic entropy and the cooling curve. Simply setting the external magnetic field to zero does not eliminate those interactions. Different refrigerants therefore need their own measured equilibrium properties; there is no universal final temperature from the applied-field ratio alone.
Finally, a real open heat switch has residual thermal conductance; supports, wires and radiation carry incoming heat. Field changes may also dissipate energy. Locally near thermal equilibrium, with incoming heat rate and internal entropy production rate , the stage balance becomesThis uses a common stage temperature; a non-equilibrated load requires separate balances. The sweep must allow spin-lattice relaxation while remaining fast enough to limit accumulated parasitic heat. At fixed , the same balance explains warming and finite hold time. Useful refrigeration is the controlled absorption of a load's heat during that finite interval, followed by a renewed isothermal process of magnetization to export its entropy.
The International Temperature Scale of 1990 is a practical scale for reproducible temperature measurements. Its assigned reference points and interpolation procedures approximate thermodynamic temperature. A calibrated standard platinum resistance thermometer transfers this scale over specified intervals; it does not define the modern kelvin.[ref]
The International System of Units (SI), ninth edition, SI Brochure. §2.3.1: practical temperature scales, ITS-90, and thermodynamic temperature
A thermometer measures temperature through a physical response whose relation to temperature is known. Examples include the length change from thermal expansion, a change in electrical resistance, and the pressure of a gas thermometer. If the response function is an injective function over the working range, its measured value determines through the inverse function. Thermometer calibration establishes that relation for the particular instrument and measurement conditions. Two matching readings are meaningful only after calibration to a common scale and with the probes sampling comparable equilibrium states. [ref]
https://openstax.org/books/university-physics-volume-2/pages/1-2-thermometers-and-temperature-scales. Ling, Moebs and Sanny, University Physics Volume 2, section 1.2: physical responses used in thermometers
For a contact thermometer, the sensing part must reach thermal equilibrium with the region being measured. That region may differ from the rest of the object: an immersed probe near a heater can read a local temperature while the surrounding water remains cooler. A stable reading can also be a steady state set by competing heat transfer paths to the sample and the room. Good contact, adequate immersion, mixing where appropriate, and checks for spatial differences help establish which temperature the reading represents. These are measurement controls inferred from the thermal equilibrium requirement, not a guarantee that every flat trace is equilibrium.
A thermometer also changes the sample it touches. Consider an original toy calculation with an initially uniform sample at , a probe at , and constant whole-body heat capacities and . Suppose together they form an isolated system, with no work or phase transition and negligible contact energy. The first law of thermodynamics and thermal equilibrium giveThe final thermometer reading underestimates the sample's original temperature by about , although it correctly measures their new common temperature. The disturbance becomes small when the participating probe heat capacity is small compared with the sample's. A large controlled heat bath is a different limit: it supplies or removes heat while approximately maintaining its own temperature.
Waiting time is a separate issue from disturbance. Under a toy Newton's law of cooling model for a uniform probe in a maintained heat bath, a constant contact conductance givesThe time constant controls this exponential decay. For stipulated values , and , the probe reads about after one time constant and after three. These are calculated values, not an instrument specification or measured data. Real probes may have multiple relaxation times and additional heat transfer paths; choose an equilibration criterion from the required accuracy, rather than assuming that a fixed waiting time works universally.
A thermometer using differential thermal expansion of a liquid and its glass container to move a column through a calibrated capillary.
A bulb-volume change shifts the indicated temperature. Contraction raises the liquid column at a fixed temperature; expansion lowers it. Permanent and temporary changes require distinction when interpreting an ice-point check.[ref]
A thermometer that infers temperature from a calibrated electrical resistance. Measuring current can heat its sensing element; extrapolation toward zero current controls that bias in the saturation-pressure equilibrium measurement.
A resistance thermometer using platinum as its sensing material. It provides the temperature readout in the saturation-pressure equilibrium measurement.
Transduction turns electrical resistance into a temperature indication. A uniform wire has , with electrical resistivity , length , and cross-sectional area . Stronger atomic vibrations at higher temperature scatter electrons more, increasing platinum's electrical resistivity; impurities and crystallographic defects also contribute.[ref]
Guide on Secondary Thermometry: Industrial Platinum Resistance Thermometers by Jonathan Pearce and others. Guide on Secondary Thermometry: Industrial Platinum Resistance Thermometers, §2.1, printed pp. 6–7: resistivity, electron scattering, and impurities
A small known electric current and measured electric potential difference give through Ohm's law; a resistance bridge can instead compare the element with a reference resistor. Inverting the calibrated response then gives the sensing element's temperature. This makes electrical readout convenient, but the platinum resistance thermometer lead resistance error, resistance thermometer self-heating, and resistance thermometer immersion test explain why a stable display alone is insufficient. The gas thermometer supplies a contrasting route through an equation of state; the saturation-pressure equilibrium measurement shows why a trustworthy independent temperature readout matters.
A standard platinum resistance thermometer uses very pure, annealed platinum with strain-limiting construction. An industrial platinum resistance thermometer commonly uses supported wire or a film. Their response curves differ.[ref]
The word standard describes the instrument's metrological role. Calibrated SPRTs realize specified interpolation intervals of the International Temperature Scale of 1990 and transfer reference temperatures to other thermometers.[ref]
Mercury Thermometer Alternatives: Platinum Resistance Thermometers (PRTs) by National Institute of Standards and Technology. Platinum Resistance Thermometers, opening explanation: SPRTs as ITS-90 interpolation tools
They are primary standards for realizing that practical scale, but their electrical resistance alone does not determine absolute thermodynamic temperature without calibration. Primary thermometry such as the corrected gas thermometer obtains thermodynamic temperature from a physical law. A reference in a comparison bath may be an SPRT; an individually calibrated industrial platinum resistance thermometer can also serve as a working reference with an appropriate uncertainty.An industrial platinum resistance thermometer is a platinum resistance thermometer built for practical measurement conditions. The label Pt100 specifies a nominal reference electrical resistance, not an SPRT, a calibration certificate, or a universal accuracy. Calibrate the probe together with its readout when the desired result is the performance of the complete indicating system.
A Pt100 has nominal electrical resistance at .[ref]
Mercury Thermometer Alternatives: Platinum Resistance Thermometers (PRTs) by National Institute of Standards and Technology. Platinum Resistance Thermometers, opening explanation: conventional 100-ohm element at 0 °C
Here is the reference for the nominal element designation; it is distinct from the water triple point used in SPRT calibration. The following Pt100 local linear model deliberately stipulates one approximate response for calculations.Choose the illustrative local modelHere is the Celsius temperature, measured relative to , so is dimensionless. For this chosen affine function, the derivative and inverse relation areCalculated values are , , , and . These are model outputs, not measurements or an assertion that any real Pt100 follows this line exactly. The number here is the chosen slope parameter; it is not a universal local derivative for all platinum resistance thermometers. Curvature, manufacturing differences, and the fitted calibration interval matter. A wider-range calibration uses a validated response curve rather than extrapolating this line indefinitely.
Chosen Pt100 line and an illustrative calibration with an independent check
. The left panel plots the Pt100 local linear model. The right panel uses stipulated values for a different illustrative element: two points set a line, while a third point tests it. Every point is synthetic; none is measured calibration data or a tolerance band. Source. Details.For a separate synthetic thermometer calibration, stipulate at and at . A two-point affine function has slope and givesThus would indicate . If an additional synthetic check at reference instead supplied , the line would indicate . The residual exposes disagreement that two fitted points cannot reveal. This separate example changes both offset and slope; it is not a replacement specification for the nominal Pt100 local linear model.
A 1998 NIST account describes stirred comparison baths, a reference SPRT with a 30 Hz resistance bridge, and a temperature-controlled reference resistor. The test IPRTs used a current source, a scanner, and an 8½-digit voltmeter. Separate current and voltage leads made each test probe a four-terminal device; readings in both current directions supplied voltage ratios to the reference resistor.[ref]
A New NIST Automated Calibration System for Industrial-Grade Platinum Resistance Thermometers by Gregory F. Strouse and others. A New NIST Automated Calibration System for Industrial-Grade Platinum Resistance Thermometers, §§3.1, 3.3 and 4.2, printed pp. 2–6: baths, readout, four-terminal devices and reversed current
Its program bracketed test readings with reference SPRT readings and repeated a block if bath drift was excessive. A check SPRT monitored the system; reference water-triple point measurements checked stability. Sensor depths were matched, and unfamiliar probes underwent immersion tests. Ice and water-triple point readings before and after calibration checked changes. Additional points could test the fitted curve. Reported calibration uncertainties excluded transport, subsequent drift, hysteresis, and the user's measurement system. These are controls and limits of that documented apparatus, not an accuracy promise for all platinum resistance thermometers.[ref]
The inference is a pair: reference temperature from the SPRT, test electrical resistance from the electrical readout. Record measuring electric current, wiring, immersion, and the stated reference scale with each pair. A bath controller's setpoint is not itself the calibrated reference temperature. Returning to a reference and checking intermediate points distinguishes a fitted relation from a reproducible calibration over the intended interval.
With two shared leads of electrical resistances , Ohm's law givesUsing the Pt100 local linear model, positive lead electrical resistance appears as a warmer temperature. At true , stipulated leads of each change into , producing : a calculated bias of about . Subtracting a measured loop correction works only while that loop electrical resistance remains appropriate; cable temperature changes can invalidate it.
Four-terminal sensing separates the electric current and electric potential difference leads. Negligible sensing electric current suppresses sensing-lead drops; force-lead drops lie outside the interval. Real voltmeter loading, connections, and leakage still need checking.[ref]
For a stable offset from the thermoelectric effect, two signed electric potential differences obey and . The current-reversal calculation in four-terminal sensing yieldsAt stipulated , and , and recover exactly in this model. If the offset or sample temperature changes between readings, cancellation is incomplete. Reversal also leaves Joule heating unchanged because it depends on .
Measuring electric current creates Joule heating, raising the sensing temperature. At fixed bath temperature, compare settled readings at and and extrapolate the approximately linear dependence toward zero current.[ref]
Guide on Secondary Thermometry: Industrial Platinum Resistance Thermometers by Jonathan Pearce and others. §4.1, printed pp. 24–26, equation (4.1.1): self-heating, two-current extrapolation, and medium dependence
Under the local model ,For synthetic readings at and at , the extrapolated value is . The lower-current excess corresponds to in the Pt100 local linear model. At , dissipates ; power alone does not specify a temperature rise without a thermal coupling model. These stipulated values are not measurements.
Repeat the comparison after settling and test the approximation if necessary. Changing from liquid to air changes heat transfer; a self-heating correction need not transfer unchanged. The saturation-pressure equilibrium measurement provides an existing example of controlling this disturbance in resistance thermometry.
A probe's sheath and leads carry heat between the sensing region and the surroundings through thermal conduction. In a stable, sufficiently uniform heat bath, compare the indicated temperature as insertion depth increases, allowing settling each time. A plateau supports adequate immersion for that apparatus and required uncertainty; it does not prove that every depth or medium works. Keep the sensing element and reference thermometer at comparable depths, and check bath gradients independently, so moving the probe does not merely sample a different temperature. The documented platinum resistance thermometer comparison calibration includes these controls.
A thermistor is a temperature-sensitive resistor used as a resistance thermometer. Its calibrated electrical resistance supplies a temperature indication; probe heat capacity and unwanted thermal conduction can affect its response and immersion error.
A gas thermometer infers temperature from the equation of state of a confined gas. The constant-volume version measures pressure; the constant-pressure version measures volume. For an ideal gas,Here is particle number, is amount of substance, is the Boltzmann constant, and is the molar gas constant. The reference and test states must be internally equilibrated, and must be known on the absolute thermodynamic temperature scale. A pressure ratio cancels the unknown gas inventory and bulb size in the ideal constant-volume limit. This cancellation is the method's appeal: a mechanical measurement transfers an absolute temperature scale between different materials. The Maxwell speed distribution and ideal gas pressure from wall collisions explain the microscopic origin of the response. [ref]
2.1 Molecular Model of an Ideal Gas. OpenStax, University Physics Volume 2, section 2.1: the ideal gas law
For an original ideal-model calculation, choose , and . Then . These are stipulated values, not observations. Both pressures must be absolute, referred to vacuum. If the surrounding atmospheric pressure were , the corresponding gauge pressures would be and ; their ratio is three, which would incorrectly predict . A pressure difference from the atmosphere cannot be substituted into the ideal gas law.
An original schematic of constant-volume gas thermometer measurements
. Simplified measurement layout inspired by the NBS apparatus, not a replica or a report of measurements. A controlled bath thermalizes the bulb, separate calibrated thermometers check its surroundings, and a diaphragm transmits pressure to an absolute-pressure standard without mixing gases. The connecting tube contains gas at other temperatures; its inventory belongs in the gas thermometer dead-space correction. Details.A motivating calibration experiment. Schooley's account of the NBS/NIST work describes a helium-filled metal bulb, a capillary, a capacitance diaphragm gauge, and a mercury pressure standard. Circulating bath liquid passed the bulb assembly and platinum resistance thermometers. The resistance probes checked the surrounding temperature; gas pressure supplied the independent thermodynamic comparison. In an early series, workers filled the cleaned bulb with purified helium at the highest test temperature, checked pressure over three hours, then measured at lower temperatures and near a reference at . Six filling pressures allowed extrapolation toward zero pressure. [ref]
To turn this principle into a readable measurement protocol, use the following controls. These steps are a proposed teaching interpretation of the cited apparatus, rather than additional reported NBS observations:
- Define the inventory. Evacuate and clean the bulb and connecting tube, fill with a known pure gas, close the filling valve, and keep the same total particle number during each reference/test comparison. Monitor pressure at a maintained temperature before and after a run. A leak changes ; a slow drift can also reflect contamination, sorption, or imperfect equilibration, so pressure stability alone does not identify its cause.
- Measure the reference. Place the bulb in a controlled environment with independently assigned . Record after thermalization, together with the independent thermometer readings and their spread. A reference near has an absolute temperature near , rather than zero temperature. Repeating reference readings tests whether the inventory or apparatus changed during the comparison.
- Measure the test state. Change the bath setting, allow the bulb and gas to settle, and record only when the surrounding thermometers and pressure are sufficiently stable for the intended accuracy. Compare readings at different positions and vary the settling time. Record the connecting tube's temperature profile too: uniform bath temperature does not make the entire connecting tube isothermal.
- Measure the volume changes. Determine the bulb's thermal expansion and its deformation from differences between inside and outside pressure. Measure the connecting tube's dimensions and the effective valve volume. “Constant volume” is the ideal model; a real vessel expands. These measurements supply corrections, even though the absolute bulb volume cancels in the simplest pressure ratio.
- Measure pressure against a reference. For a liquid-column pressure standard, measure the vertical column height, the liquid's temperature-dependent mass density, local gravitational acceleration, and the reference-side pressure. Include diaphragm offsets and the gas's hydrostatic pressure change between the sensor and bulb. The pressure needed in the equation of state is at the bulb, not automatically at the remote gauge.
The corresponding NBS apparatus used a protective case with an outer helium layer held close to the bulb pressure, reducing pressure deformation while aiding thermal contact. Thermal expansion was measured on bulb material. Gas in the capillary remained partly outside the hot region, requiring a measured tube temperature profile and geometry. Pure working gas also mattered: contaminants that sorb on surfaces can change the freely circulating inventory. These are physical effects to measure or bound, rather than scatter that disappears by averaging. [ref]
https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nbsir85-3133.pdf. J. F. Schooley, Thermometry, NBS IR 85-3133, chapter V, gas thermometry and the NBS experiment
For illustration, neglect connecting-tube gas and describe a uniform bulb with a dilute virial expansion in particle number density :Here and is the second virial coefficient in the particle-density convention; a molar-density convention rescales the coefficient. The second relation follows exactly from the definition of for the same , and shows the signs of the corrections. If the bulb expands by and at both states, the toy pressure ratio above gives , rather than . Improved expansion and helium nonideality models really changed the temperatures inferred from the 1989 NIST data: Harvey's 2023 reanalysis found expansion updates of roughly – and nonideality updates of roughly to . Those are reported corrections to historical results, not the much larger illustrative correction just calculated. [ref]
With equal corrected bulb volumes, negligible or corrected connecting-tube gas, fixed reference and test temperatures, and a dilute classical single gas phase,Repeat the reference/test comparison for several sealed fills, reducing between comparisons but keeping it fixed within each pair. The extrapolation varies density at fixed endpoint temperatures; it does not cool one fill toward zero temperature. Real gases have different finite-density corrections but share the classical ideal gas intercept under these assumptions. The limit does not remove leaks, bulb expansion, gauge offsets, or the gas thermometer dead-space correction. At very low pressures, thermal transpiration can make remote sensor and bulb pressures differ through a nonisothermal capillary; this must be corrected too. The NBS work measured this pressure correction using a separate comparison of narrow and wider tubes. [ref]
At , the toy models give and , respectively, although their imposed true test temperature is the same. Their zero-density intercept is the reusable quantity. Measuring several low-density points permits a fit and a check for curvature; asserting a straight line from one finite-density point supplies neither. A practical fit must balance nonideality against increasing relative pressure error and the capillary corrections, and keep its extrapolation uncertainty.
Gas outside the uniform-temperature bulb of a gas thermometer contributes to its conserved particle inventory. An idealized calculation divides the connecting tube into small regions with volumes and local temperatures . Neglect hydrostatic pressure offsets and thermal transpiration, assume a common pressure and a local ideal gas law in each region, and let the bulb have volume and temperature . Adding the particle inventories givesThus even an ideal gas in a perfectly rigid sealed apparatus need not obey : some of its particles remain in regions with other temperatures. For a stipulated bulb of , a connecting volume of maintained at , and bulb reference and test temperatures of and , conservation of givesThese are toy dimensions and a calculated bias, not measured data. Reducing reduces both pressures proportionally and leaves this ratio unchanged: extrapolating away gas nonideality does not eliminate the connecting-volume error. Actual apparatus also requires the tube's thermal expansion, a measured temperature profile, and the pressure corrections omitted in this model.
Thermometer calibration compares an instrument's response with assigned reference temperatures under specified conditions. In a proposed two-reference procedure, thermalize the sensing part at and , record responses and , and, only if a linear response is justified over that interval, useAdditional reference temperatures test curvature; returning to the first reference tests drift. A gas thermometer instead obtains its response from an equation of state, with a reference and corrections for its apparatus. In either case, uncertainty in the reference propagates to the inferred temperature. Calibration determines the response relation; it cannot by itself remove the finite-sample disturbance or incomplete thermal equilibrium described in thermometer. A reference established on a practical scale can also differ slightly from true thermodynamic temperature; the BIPM distinguishes the International Temperature Scale of 1990 readings from their thermodynamic counterparts.[ref]
The International System of Units (SI), ninth edition, SI Brochure. section 2.3.1: practical and thermodynamic temperature
The kelvin is the SI unit of thermodynamic temperature, with symbol . Its definition fixes the numerical value of the Boltzmann constant; it is written without a degree sign.[ref]
https://www.bipm.org/en/si-base-units/kelvin. BIPM, SI unit kelvin
The degree Celsius has the same size as the kelvin, with a shifted temperature origin: . Thus a change of one degree Celsius is a change of one kelvin, but temperature ratios in Carnot's theorem must use absolute thermodynamic temperature.[ref]
Inverse temperature is , where is the Boltzmann constant and is the absolute temperature. A canonical ensemble weights an energy by its Boltzmann factor . Calling couplings dimensionless means absorbing this factor into their energy coefficients. The alternative convention makes inverse temperature ; physical and dimensionless couplings must not be mixed.
In a thermal Euclidean worldline path integral with , is also the circumference of the imaginary-time circle.
Cryogenics studies the production and use of very low temperatures. Its experimental challenge is a balance of rates: a refrigerator must remove energy from a cold region faster than unwanted heat transfer supplies it. A low temperature reading alone does not establish a useful cooling capacity. A maintained cold liquid bath is especially valuable because latent heat allows it to absorb heat while its phase fraction changes at nearly fixed temperature and pressure.
Helium liquefaction illustrates why staged cooling and recovery of a returning stream's cooling capacity matter. A counterflow heat exchanger transfers heat from the incoming stream to the colder returning stream without mixing them. This reduces the incoming specific enthalpy before expansion. The heat exchanger recovers cooling already produced; the surrounding refrigerator still requires input work and rejection of heat to a warmer environment.
A thermal connection to a controlled cold stage reduces the temperature difference caused by heat leaking through measurement leads or supports. Johnson-Nyquist noise still remains at the maintained temperature; reducing drift and reducing the noise amplitude are separate aims.
Helium liquefaction converts helium gas into a collectable liquid. It creates a bath for investigating material properties at very low temperatures, including superconductivity. The central question is how the incoming specific enthalpy compares with the specific enthalpies of the outgoing liquid and vapor. The liquefaction enthalpy budget makes that comparison explicit; a temperature decrease by itself does not specify a liquid yield.
In a Joule-Thomson effect cooling stage, a throttling pressure drop approximately preserves enthalpy under the assumptions of the steady-flow energy balance. For an ideal gas, specific enthalpy depends only on temperature: with positive specific heat capacity at constant pressure, equal specific enthalpy means equal temperature. Thus its Joule-Thomson coefficient is zero. An ideal gas also supplies no liquid branch. Cooling by throttling depends on real gas properties; expansion is not an automatic source of refrigeration.
For a local drop , cools only where the Joule-Thomson coefficient is positive. Precooling must bring the real gas into a useful cooling region, with enough cooling to overcome unwanted heat transfer. A finite expansion can cross a Joule-Thomson inversion curve; its final state requires the full enthalpy balance, including phase coexistence if liquid forms. Kamerlingh Onnes's 1908 helium liquefaction experiment combined external precooling with regeneration to reach that regime. The Joule-Thomson effect article develops the throttling identities and their assumptions.
On 10 July 1908, Heike Kamerlingh Onnes's Leiden laboratory circulated purified helium through liquid air and evaporatively cooled liquid-hydrogen precooling, a regenerative heat exchanger, and an expansion valve. Returning helium cooled incoming helium; liquid collected in a transparent vacuum vessel. Reflected light revealed its liquid meniscus, crossed by thermocouple wires. Subsequent mass density and spectroscopy checks tested contamination.[ref]
Functional stages of helium liquefaction
. Original functional diagram of the reported sequence. Arrows show stream direction and heat transfer; positions do not represent the apparatus geometry. Compression and heat rejection close the refrigeration cycle. Source. Details.A constant-volume helium gas thermometer below the valve supplied the temperature indication. An oxygen boiling reference check disagreed with its expected reading; the real gas correction to thermodynamic temperature remained provisional. A temperature plateau suggested immersion before the liquid meniscus was recognized.[ref]
The Liquefaction of Helium by Heike Kamerlingh Onnes. §4, pp. 180–181; §§5–6, pp. 183–184
The measurement principles separate two questions. A visible liquid meniscus establishes an interface; a gas thermometer estimates temperature through an equation of state. A stationary temperature trace can also result from a steady state without phase coexistence, so it cannot replace the interface observation. Conversely, seeing a liquid does not calibrate a thermometer. Thermometer calibration, the gas thermometer dead-space correction, departures from the ideal gas law and incomplete thermal equilibrium all matter when assigning an absolute temperature. A check far from the intended measurement range tests the instrument but does not by itself bound every low-temperature error.
Consider an original model of a cold section enclosing a throttle and collecting region, with the precooling heat exchanger outside its boundary. The inlet has mass flow rate and specific enthalpy . The outlets are equilibrium liquid and vapor at one fixed pressure, with specific enthalpies and . Let be the outlet liquid mass fraction, and let be incoming unwanted heat per unit incoming mass. Assume steady flow, no shaft work, and negligible bulk kinetic energy and gravitational potential energy changes. The steady-flow energy balance givesHere is the latent heat per unit mass at the chosen outlet pressure. The mass flow rates of the outlets are and . The formula describes a flowing cold section; a filling vessel with appreciable energy or mass accumulation requires storage terms.
For a deliberately dimensionless example, choosePer unit incoming mass, one quarter leaves as liquid and three quarters as vapor. With zero incoming heat, the same inlet would give . Increasing to reduces to , and reaches the no-liquid boundary. These are chosen model values, not helium property data or a historical yield. In normalized enthalpy units with and , conservation checks directly: .
An original normalized liquefaction enthalpy budget
. Each solid segment satisfies the stipulated equilibrium two-outlet model. Dashed negative continuations are algebra only: they do not describe a negative liquid mass fraction. No helium properties or experimental measurements were fitted. Source. Details.The admissible interval is , or . Outside it, the assumed equilibrium two-phase outlet fails: an enthalpy above requires a hotter single-vapor outlet under these assumptions, rather than a negative amount of liquid. Below , a colder liquid or a different thermodynamic phase must be considered. The balance does not predict its own outlet pressure, temperature or helium property functions.
At fixed outlet pressure, hence fixed , the derivatives are and . Lowering inlet specific enthalpy by regeneration and reducing incoming heat therefore buy the same increase in liquid mass fraction per unit energy per unit mass in this model. Adding any constant to all three specific enthalpies leaves unchanged. This independence of the arbitrary enthalpy reference makes the balance useful even when property tables choose different zero points.
Apply the steady-flow energy balance to an entire liquefaction apparatus, allowing a warm gas outlet and a separate cold liquid outlet. With incoming heat per unit feed mass, no shaft work, and negligible changes in bulk kinetic energy and gravitational potential energy, conservation of mass and conservation of energy give . Solving this equation gives the displayed liquid mass fraction.
The two outlet streams need not share a temperature. For example, a counterflow heat exchanger can warm returning gas before it crosses the overall control volume boundary, while collected liquid leaves at the cold end. When the outlet temperatures differ, includes sensible heating as well as phase change; it is not simply a latent heat. A colder two-phase separator nested inside the apparatus has its own boundary states and a different local enthalpy balance.
Thermal boundary resistance describes a temperature drop between the two sides of a material interface carrying heat flux. Efficient thermal conduction within each material does not guarantee efficient heat transfer between them. The solid–helium case is Kapitza resistance; the broader concept also includes solid–solid interfaces. [ref]
Let and be the temperatures extrapolated to the interface from its solid and liquid sides, each treated as internally in thermal equilibrium. For uniform normal heat flux through area , define the finite-drop, area-specific thermal resistance and the resistance of the whole interface byThe macroscopic jump represents an unresolved interfacial region; it is not a claim that one point has two equilibrium temperatures. At nonzero heat flux, the two sides are outside mutual thermal equilibrium. A measured difference between distant thermometers also contains bulk temperature gradients, which must be measured or bounded before assigning all of it to the interface.
An energy balance explains why a temperature jump can coexist with continuous heat flux. For a stationary interfacial region with no local work or heat source,The first law of thermodynamics therefore requires in a steady state. It does not require . For a heated sample with electrical power , an independently determined outward parasitic loss and no other inputs,Here is the heater's electric potential difference and its electric current. Subtracting a lead loss means subtracting power before dividing by area; is not the total heating power. Unknown losses and stored internal energy prevent that simple steady inference.
For a one-dimensional comparison, put an interface between two slabs with the same area , positive constant thermal conductivities and lengths . Neglect side losses. Integrating Fourier's law across each slab givesThus, for a linear interface with constant , the series result isThese slab formulas are a chosen thermal conduction model, not a bulk transport law for moving liquid helium. If the interface law is nonlinear, substitute its own relation between and into the preceding balance; a single constant resistance cannot describe every load. Increasing bulk thermal conductivity has diminishing benefit when the interfacial drop dominates. Increasing usable contact area reduces the whole-interface thermal resistance if the local interface law and the other conditions remain fixed.
Kapitza resistance is the thermal boundary resistance encountered between a solid and helium in cryogenics. A cold helium heat bath can coexist with a warmer immersed component under continuous heating. The bath's temperature alone therefore does not establish the component's temperature. Kapitza thermal boundary experiment supplied an early direct demonstration of the obstacle at the solid–liquid boundary.
A microscopic route to interfacial heat transfer is transmission of phonons. Transmission depends on the two materials and their interface; scattering and the condition of the surface matter. [ref]
Thermal boundary resistance by E. T. Swartz and Robert Otto Pohl. Swartz and Pohl (1989), abstract: phonon transmission, scattering and surface sensitivity
The fourth-power thermal boundary model isolates one useful low-temperature limiting law without assigning an empirical coefficient to a particular sample.Pyotr Leonidovich Kapitza's 1941 study suspended cleaned, annealed copper blocks in liquid helium. Sealed, gas-filled cavities held a heater and a bronze resistance thermometer. Electrical readout tracked the heating-induced temperature rise; the earlier readout method assumed a stable bath without a separate bath thermometer. A nearby unheated block warmed much less, localizing the drop near the heated surface. Gold plating and coatings tested surface effects; tight cavities prevented liquid ingress. These were solid-body readings, not probes resolving the microscopic interfacial layer. [ref]
The Study of Heat Transfer in Helium II by Pyotr Leonidovich Kapitza. The Study of Heat Transfer in Helium II, chapter 38, §2 pp. 584–585; §6 pp. 616–621, Figs. 25–29
The measurement logic suggests a modern control sequence: calibrate both temperature readouts, establish their zero-load difference, increase heater power, wait for a steady state, and repeat while monitoring the bath. Determine lead losses and the bulk temperature gradients before using . These are proposed controls derived from the energy balance, rather than additional reported steps in the 1941 apparatus. A nearby unheated solid also has its own interface: its reading need not equal the liquid's local temperature exactly. The experiment supports a drop concentrated near the surface, while a microscopic thickness and a universal interfacial law require further evidence.
Choose a positive constant and the illustrative interface lawHere and are the hot and cold interface-side temperatures, not distant thermometer readings. This is a low-temperature phonon model under restrictive assumptions, not a universal fit to Kapitza's measured exponent or a material-property table. Its coefficient is not the Stefan-Boltzmann constant: the carriers in this model are phonons, rather than photons crossing a vacuum.
The fourth power has a simple counting explanation. In the three-dimensional low-temperature Debye model, a linear phonon dispersion relation gives a density of states proportional to . A phonon has energy and Bose-Einstein distribution occupation . If propagation speeds and the angle-averaged transmission introduce no additional frequency scale over the occupied modes, the outgoing energy flux has the formExtending the upper integration limit assumes occupied modes lie well below the cutoff. Balancing the two outgoing fluxes, with coefficients satisfying zero net heat flux at equal temperatures, gives the chosen difference of fourth powers. Frequency-dependent transmission, different excitations or additional transport channels can change this conclusion.
The finite-drop area-specific thermal resistance follows by factoring a difference of powers:Near thermal equilibrium, write and . Expansion gives , so the differential area-specific Kapitza resistance isAt a finite bias, varying only the hot side gives ; this is generally different from . Stating what is held fixed makes a differential resistance reproducible.
For an original normalized example, choose reference scales and , and setFor contact area , the total heat transfer rate is . The finite-drop resistance satisfies . Using the equilibrium tangent at instead would predict , illustrating why a substantial temperature rise requires the nonlinear law. Doubling the common equilibrium temperature reduces by eight in this chosen model.
A series check can be done without guessing any material properties. Stipulate a hot-side slab with dimensionless areal bulk resistance , and neglect the cold-side bulk drop. At the same , the hot reservoir must have . The imposed reservoir drop splits into in the bulk and at the interface. Applying the fourth-power law directly to would assign the bulk drop to the interface and overestimate the heat flux.
Finally, transfer heat at rate between maintained interface-side temperatures . The hot side loses entropy at rate , and the cold side gains it at rate . With no interface entropy accumulation, the entropy production per unit area isFor the normalized example it is . The same energy crosses both sides in a steady state, while total entropy increases, consistently with the Second law of thermodynamics. A finite temperature jump during heat transfer therefore expresses dissipation, not a failure of energy conservation.
Articles by others on the same topic
Temperature is a measure of the average kinetic energy of the particles in a substance. It quantifies how hot or cold an object is and is a fundamental parameter in the study of thermodynamics and physics. Temperature can influence various physical and chemical properties of materials, including their state (solid, liquid, or gas), pressure, and volume.
For scales from absolute 0 like Kelvin, is proportional to the total kinetic energy of the material.