Bearing thermal stiffness identification

ID: bearing-thermal-stiffness-identification

Bearing thermal stiffness identification uses measured force changes along a specified thermal path, together with independently known expansion behavior, to infer the axial restraint of an assembly. The observed bearing thermal reaction slope is inN/K. Mechanical stiffness is force per displacement, so converting into stiffness requires the free relative-expansion rate in displacement per temperature. In the constant-compliance engaged model,
Here and represent the bearing and supporting structure's axial mechanical compliance contributions.
For an original identification example, suppose equilibrated engaged measurements give forces160,320 and480N at temperature increases50,60 and70K. A linear regression gives slope16N/K and, within this model, an extrapolated zero-force engagement increase of40K. If an independent free-expansion measurement gives , the total compliance is and total stiffness is . A16N/K thermal slope is therefore not itself a16N/m spring stiffness.
The measurements have an identifiability limit: the slope determines when is known, rather than determining both contributions separately. A known supporting-structure compliance would imply . Without that extra information, many pairs give the same total. If is also unknown, scaling both and total compliance by the same positive factor leaves the measured slope unchanged.
A bench experiment can measure axial force with a load cell, track shaft and housing temperatures, wait for equilibrated states and fit only measurements from the engaged regime. A separate low-restraint expansion measurement can estimate . Repeating heating and cooling helps test whether friction, changing contact or thermal gradients invalidate the assumed single slope. These are proposed measurement steps, not a claimed manufacturer's experiment. The physical motivation is the need to accommodate relative thermal displacement in a locating/non-locating bearing arrangement.[ref]
For independent and , first-order propagation gives
For with standard uncertainty0.1µm/K and with standard uncertainty0.8N/K, the inferred total compliance has standard uncertainty about0.00884µm/N. Correlated temperature references require the corresponding covariance contribution rather than this independent-input expression.[ref]