The critical fibre length is the minimum embedded fibre length needed to develop a specified tensile stress in a simple interfacial-load-transfer model. For diameter , fibre strength and constant limiting interfacial shear stress ,Each half of the fibre builds axial force from its end through interfacial shear; balancing that transferred force against the strength load gives the formula. It is a model-dependent criterion, not a universal length of the material. Nonuniform shear, imperfect bonding and fibre orientation modify actual composite behavior.