Effective regurgitant orifice area

ID: effective-regurgitant-orifice-area

The effective regurgitant orifice area is a flow-equivalent area for a leaking heart valve: the instantaneous backward volume flow rate divided by the corresponding jet speed ,
It characterizes the effective stream passing through the leak. It need not equal the anatomical opening traced on an image, because flow contracts and its velocity is not uniform across every geometric surface. The vena contracta and the upstream convergence pattern provide complementary flow information.[ref]
The proximal isovelocity surface area method illustrates how an area can be inferred without drawing the hole itself. Color Doppler identifies an upstream surface at a selected aliasing speed . In an ideal hemispherical convergence model of radius , conservation of mass gives
Continuous-wave Doppler echocardiography supplies the jet speed. The convergence radius and jet speed must refer to matching times. The hemisphere is an assumption about flow geometry, not a property guaranteed by the instrument.[ref]
For an original model calculation, let cm, cm/s and cm/s. Then mL/s and . At otherwise fixed inputs a ten-percent radius overestimate multiplies the inferred area by . The radius-squared dependence explains why a small geometric measurement error can matter substantially.
An instantaneous effective area and an integrated regurgitant volume answer different questions:
If the effective area is constant, this becomes using the velocity-time integral. A stipulated VTI of 150 cm with the calculated constant area gives 36.19 mL. A single peak area generally cannot be pulled outside the integral when the leak changes during systole. Alternatively, defines a velocity-weighted mean effective area over that interval. The technical report explicitly distinguishes instantaneous convergence measurements from temporally varying regurgitation.[ref]