Gradient zeroth moment

ID: gradient-zeroth-moment

The gradient zeroth moment is the signed time integral of an effective magnetic field gradient waveform along a specified encoding axis:
Its units are tesla seconds per metre. Effective means that the sign convention accounts for any refocusing pulses in the nuclear magnetic resonance sequence; it is not necessarily the unsigned physical pulse area.
For a stationary spin at position , choose the phase convention . Then , where is the angular gyromagnetic ratio. A balanced waveform with cancels this position-dependent contribution within the model. It does not assert that every possible background contribution to phase vanishes.
As an original rectangular-pulse example, for has . Adding for cancels it. Equal areas, rather than equal pulse heights, produce the balance.
For a moving spin with , the remaining contribution can be , involving the gradient first moment. That separation explains how magnetic resonance velocity encoding can suppress sensitivity to stationary position while preserving motion information. Early phase-sensitive flow imaging supplied the experimental motivation for extracting such information from resonance phase.[ref]

New to topics? Read the docs here!