Indoor-temperature limit of a Carnot heat pump
ID: indoor-temperature-limit-of-a-carnot-heat-pump
A reversible heat pump maintaining against an external has heating coefficient of performance . If its maximum work input is and the building loses heat at rate , maintaining equilibrium requires . This yields the displayed minimum external temperature, provided it lies in the physical positive-temperature range. If the rating instead specifies maximum delivered heat, the bound is ; a heat-output rating cannot be substituted for a work-input rating in the Carnot formula.