For the cyclic two-side energy balance in refrigerator, define the dimensionless cooling and heating coefficients byThis identity applies even to irreversible machines, provided both coefficients refer to the same operating point, work input and boundary with no additional energy transfer or storage. It does not compare two separately operated appliances. Unlike thermal efficiency of a heat engine, a COP can exceed one: its numerator counts heat moved, including energy taken from another region. [ref]
https://labs.phys.utk.edu/mbreinig/phys136core/modules/m3/refrigerators.html. University of Tennessee, Refrigerators, air conditioners, and heat pumps: the two performance ratios
To obtain temperature-only bounds, impose stronger assumptions: a cyclic machine exchanges heat only with two ideal thermal reservoirs maintained at uniform, fixed absolute thermodynamic temperatures , and receives work through an ideal input carrying no entropy. Include the machine and the heat transfer interfaces in the entropy production accounting. Because its own entropy returns to its initial value each cycle, the Second law of thermodynamics givesCombining this inequality with givesEquality requires a reversible thermodynamic process for the entire cycle and its contacts, as in a reversed Carnot cycle. These are Carnot's theorem bounds independent of the working substance. Use kelvin values, not degree Celsius readings, in the numerators; the temperature difference can be expressed in either unit. [ref]
https://web.mit.edu/16.unified/www/FALL/thermodynamics/notes/node25.html. MIT, Refrigerators and heat pumps: reversed Carnot cycle and absolute-temperature cooling bound
[ref]https://openstax.org/books/university-physics-volume-2/pages/4-5-the-carnot-cycle. Ling, Moebs and Sanny, University Physics Volume 2, §4.5: reversible reservoir entropy balance
The diagram fixes and sets , so the reversible bounds are and . The stipulated machine with and satisfies both. Its reservoir entropy production per cycle is . Increasing the temperature lift at fixed lowers both bounds. Equivalently, delivering fixed needs at leastThese expressions reveal why a small temperature lift is attractive. Their divergence as is an ideal reversible limit, not a promise of infinite heating or cooling power. For finite heat transfer rates, the working fluid must be colder than the cold bath and hotter than the hot bath; these contact differences produce entropy and increase the internal temperature lift. Dissipative compression and the pressure-reducing restriction of vapor-compression refrigeration supply further departures from reversibility. Thus bath temperatures set an outer bound, not a prediction of real COP. [ref]
https://web.mit.edu/16.unified/www/FALL/thermodynamics/notes/node25.html. MIT, Refrigerator hardware: working-fluid temperatures on either side of the baths