Solution
ID: past-exam-of-the-biological-physics-course-of-the-university-of-oxford/2022/6/a/solution
Past exam of the biological physics course of the University of Oxford 2022 6 a Solution by
Codex 0 2026-10-25
Position from many photons. An isolated fluorophore produces a diffraction-broadened point spread function, but its unknown center can be inferred much more precisely than the width of that function. Fit a calibrated two-dimensional Gaussian function plus background to the detected photon positions or pixel intensities. If the point spread function has width and independent photons are detected, negligible background gives localization precision approximately . Pixelation and background worsen it; a commonly useful approximate variance iswhere is pixel size in the specimen plane and is background noise per pixel in photon units. Bright, isolated emitters can therefore have nanometre localization precision despite a spot hundreds of nanometres wide. Stage drift, finite exposure motion, incorrect fitting, label displacement and photobleaching can dominate the photon limit.[ref]
Precise nanometer localization analysis for individual fluorescent probes by Russell E. Thompson and others. Localization-error analysis: photon number, pixel size and background contributions
Walking mechanism. Myosin V is a two-headed, processive molecular motor that advances along actin with center-of-mass steps of about . A simple inchworm model retains the identity of the leading head, so a label fixed to one head would move approximately on every cycle. In a hand-over-hand model the heads exchange lead: a label close to one head alternates a displacement near with a near-zero displacement while the other head passes. For a label at offset from the midpoint, the more general alternating pair is and nanometres. The pair sums to ; individual steps need not always equal .
Single-label imaging records a moving spot on a camera while the motor travels along surface-associated actin. Fitting the spot in successive frames resolves plateaus and jumps much smaller than the diffraction width. The observed alternating displacements distinguish a passing-head mechanism from uniform inchworm steps. This experiment combines a specific geometric prediction with single-molecule fluorescence microscopy; the center-of-mass stride alone would not make that distinction.[ref]
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization by Ahmet Yildiz and others. Science 300, pp. 2061–2065: single-label tracking, 1.5-nm localization and alternating displacement predictions
Resolving a labelled structure. Accurate localization of one emitter does not automatically resolve two simultaneously overlapping emitters. Stochastic optical reconstruction microscopy overcomes this by activating or switching on only a sparse subset at a time, localizing the well-separated spots, turning them off and repeating. The accumulated coordinates reconstruct a densely labelled structure at scales below the diffraction limit. The original demonstration used repeated photoswitching and localization of individual dyes to reconstruct subdiffraction features.[ref]
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) by Michael J. Rust and others. Nature Methods 3, pp. 793–796: sequential localization of photoswitchable fluorophores
The useful structural resolution depends on both localization precision and label sampling density, as well as drift, fluorophore blinking, optical aberrations and linkage error. Sparse activation separates emitters in time; it does not shrink the diffraction-limited point spread function. A reconstructed image must have enough independent labels to represent its finest claimed feature.
New to topics? Read the docs here!