Solution

ID: past-exam-of-the-laser-science-and-quantum-information-processing-course-of-the-university-of-oxford/2022/2/d/solution

For a symmetric confocal optical resonator, the mirror separation equals either mirror's curvature, , so its symmetric fundamental Gaussian beam has
The same optical mode matching calculation applies, now with . Keeping the example's gives and , compared with for the nonconfocal target. With , the two branches become
Again only the positive- branch fits the stated downstream geometry. The confocal target's smaller Rayleigh range means a smaller fundamental beam waist at the same wavelength and a less stringent minimum .
A confocal optical resonator also has transverse normal mode degeneracies: in the ideal paraxial spectrum, increasing transverse order by two shifts the resonance by one longitudinal spacing. Such a cavity can transmit combinations of higher transverse normal modes at a fundamental resonance, so transmitted power alone is a weaker diagnostic of pure fundamental optical mode matching. The degeneracy does not remove the complex beam parameter matching requirement if the objective is specifically the symmetric fundamental Gaussian beam.