Solution

ID: past-exam-of-the-mphil-in-micro-and-nanotechnology-enterprise-course-of-the-university-of-cambridge/2019/paper-1/section-b/12/v/a/solution

The duty cycle is the fraction of time spent active. At a constant supply voltage and with switching energy neglected,
For , the average current is . Thus . Multiplying only the active power by the duty cycle would omit the sleep contribution.