For a selected lepton sample, subtract backgrounds and correct for detector acceptance, reconstruction and particle-identification efficiency, trigger efficiency and live time. Schematically,
The first expression applies when the published signal definition is a specified fiducial region; the second additionally extrapolates by acceptance . Resolution-induced migration across selections must be unfolded or included in a detector-response fit. Tau lepton reconstruction also needs the relevant branching fractions if only selected decay modes are counted. Initial- and final-state QED radiation and beam-energy spread change the measured line shape; extracting a Born-level or pole cross section requires the corresponding radiative corrections. In the electron channel, Bhabha scattering also has a non-annihilation -channel contribution that must be treated.
For quarks, hadronization means the detector observes hadrons and jets, rather than free quarks. Correct the selection and any flavor tagging using fragmentation and decay modeling, including losses to heavy-hadron decays with neutrinos. In comparison with a pointlike lepton cross section, also include the three color charges per quark flavor and QCD corrections, schematically with at high energy. The color multiplicity is a physical production factor, not an extra factor by which to divide an already efficiency-corrected inclusive hadronic event count.